PosarikaInstallation of combined cold storageInevitable development
2023-09-22 10:44:22The polyurethane insulation board shall be connected by plug-in notch connection, because it has higher strength when connecting in this way.Cold storage design steps: selection and preparation of cold storage location. According to the application characteristics, cold storage can be divided into sexual cold storage retail cold storage and large-scale cold storage. When large-scale cold storage starts to build a planting area with more centralized hand supply, factors such as superior geographical location and contact with the market should also be taken into account. The cold storage should be located in a cool place without sunlight and frequent warm air. Small and medium-sized cold storage should be built in the room. cold storagePosarika,Heat pump, hot water, refrigeration and other fields. Supporting downstream products include: household air conditioner, multi on-line, modular machine,PosarikaMeat cold storage installation company, small water ground source heat pump, etc. At present, a single scroll refrigeration unit can achieve ~ HP.Regular oil discharge, descaling and air discharge: when there is a .mm thick oil film in the evaporator coil, in order to maintain the set temperature requirements,PosarikaInstallation of second-hand cold storage, the evaporation temperature will decrease by ℃ and the power consumption will increase by more than ; When the scale on the water pipe wall in the condenser reaches mm, the condensation temperature will rise by ℃ compared with the original temperature, and the power consumption will increase. When the refrigeration system is mixed with non condensable gas and its partial pressure reaches .mpa, the power consumption will increase by about . It can be seen that it is coldRoquetas de Mar ,During the production of cold storage, the cold storage will produce fixed length, width and thickness according to the needs of various cold storage projects. Generally, cm thick cold storage plates are selected for high and medium temperature cold storage. The requirements for cold storage engineering plates of low-temperature storage and quick-frozen storage will be higher. Professional cold storage installation, installation, construction, fruit fresh-keeping cold storage and medical cold storage ensure the quality, Guarantee service. Guarantee quality. Your satisfaction is our pursuit! Welcome to inquire. In this case, you can make a reservation according to the specific conditions of your cold storage temperature. If you don't make a reservation for the cold storage plate, you should pay attention to the density of the cold storage plate and the thickness of the steel plate when purchasing the cold storage plate. According to regulations, compressor, and other components in the cold storage can reasonably adjust the evaporation and condensation temperature, so as to improve the reduction of power consumption and reduce the production cost. Professional cold storage installation, installation of cold storage, cold storage construction, fruit preservation cold storage, medical cold storage, quality assurance professional, timely supply and high cost performance. It has become the preferred brand for many wire products. Welcome to buy! Save more resources.The installation of top warehouse plate should be carried out alternately with the installation of wall plate, and the wall plate should leave a gap for withdrawing construction equipment; During the installation of the top warehouse plate, the end steel sheet at the overlap with the wall plate shall be disconnected for mm to prevent the cold bridge from running cold; Two layers of foaming materials shall be evenly and continuously punched on the joint surface between each top warehouse plate. Rivets shall be pulled and fixed at the internal and external lap joints of the steel plate, and the rivet spacing shall be mm; According to the design drawings, columns and supporting steel frames in the warehouse, the setting out and positioning shall be carried out and accurate and clear marks shall be made according to the requirements of the design drawings; Weld or install the support beam, column, support steel frame, etc., and the welded junction shall be moisture-proof and treated according to the drawing requirements.
Cold storage design segmentation: several different partitions shall be reasonably planned and divided according to purpose and temperature. For example: processing room, quick freezing room, refrigeration room, channel, unloading platform, etc.For the installation of power distribution system, each contact shall be installed with wire number for maintenance.Cold storage design step: the selection of cold storage refrigeration system the selection of cold storage refrigeration system is mainly the use of cold storage refrigeration compressor and air conditioning evaporator. Generally, small and medium-sized refrigerators are dominated by fully enclosed refrigeration compressors. Due to the small output power of the fully enclosed refrigeration compressor, the price is relatively cost-effective; Small and medium-sized refrigerators are generally dominated by semi closed refrigeration compressors; Semi closed refrigeration compressor is adopted for large and medium-sized refrigerated warehouses. When adopting, ammonia refrigeration unit can also be considered. Because the output power of ammonia refrigeration unit is large and can be used for machine use, but the installation and management of refrigerated warehouses are cumbersome. When using the air-conditioning evaporator the high-temperature cold storage uses the industrial cold fan as the air-conditioning evaporator. Its characteristic is that the temperature reduction speed is faster, which is characterized by very good temperature control effect and moderate cold storage.Create brilliance but it is easy to lead to the water consumption of the cold collection; Medium and ultra-low temperature refrigerators are dominated by seamless evaporation pipe slots,Precautions for purchase and shipment when using the medical cold storage project, the speed must be strictly guaranteed during the purchase and shipment of products. If the temperature of the medical cold storage is about degrees the opening time must be strictly within minutes. If the temperature of the medical cold storage is left and right degrees, the opening time can not be too high, strictly within minutes.When the cold storage is built, it will not only increase the cold consumption of the cold storage, but also bring moisture into the warehouse. Moisture condensation will damp the heat insulation structure and freeze and damage the cold storage structure. Therefore, it is necessary to set moisture-proof and heat insulation layer, professional cold storage installation, installation of cold storage, cold storage construction, fruit fresh-keeping cold storage, medical cold storage and other products, sell well at home and abroad, and have a long service life! Products lead the wire industry. Welcome to inquire, so that the cold storage building has good sealing, moisture-proof and steam isolation performance.First, use a hammer to pad the wood on the polyurethane warehouse board between the two warehouse boards, so as to make the boards closely close to each other. Two sets of connecting pieces shall be wedged between the wall panel and the wall panel and the two sets of connecting pieces shall be fixed on the upper, outer and lower sides of the gap between the wall panel and the wall panel respectively. The lower connecting piece shall be as close as possible to the lower side, so that the post cast concrete can cover the connecting piece. After the gap between the plate and the plate ground is wedged with a connector, it shall be about mm wide. If it does not meet the requirements, remove the plate, trim the plate edge, and then reinstall it to make the plate joint meet the requirements. When fixing the adapter, pay attention to fix the two parts of the adapter on the edges of the convex and concave library plates respectively, and fix them with rivets. The spacing of the adapter should be able to tension the two library plates. When wedging the wedge iron the hammer shall be perpendicular to the wedge iron to prevent damaging the warehouse plate. The ground wedge iron at the upper and lower parts shall be wedged at the same time, and the wedge iron shall be fixed with rivets.
Generally, in the actual operation of the refrigeration system, because the temperature conditions are constantly changing, only by relying on the careful operation of the cold storage management personnel and accurately adjusting the operation of the refrigeration equipment of the cold storage, can the refrigeration system always be in the ideal working state and achieve the effect of energy saving.Where can I find it?,Floor insulation of medium-sized cold storage the structure of medium-sized cold storage is what we often call the surface, that is, the top and wall are made of color steel plate / stainless steel with appropriate thickness of polyurethane and other insulation materials, while the ground needs to be insulated separately. At present, the common operations in the market are: laying the ground with XPS extruded board, laying moisture-proof and steam isolating SPS materials above and below the extruded board respectively, and then pouring concrete or reinforced concrete.The materials of refrigerator doors are the supporting facilities of refrigerator board, but the types of doors include manual sliding door, manual electric sliding door, fully automatic return door, electric door, cleaning door, fully buried and semi buried. Refrigeration compressor units have many common well-known brands. They are not only air-cooled and water-cooled, but also fully enclosed and semi enclosed. In the case of choice, we must do better and find a suitable one for you.Whether the water pump works normally and whether the moldy switch is effective. In case of abnormality, timely handle the overhaul and maintenance of the refrigeration compressor in the cold storage: generally, the refrigeration oil and drying filter shall be replaced times after the operation of the cold storage equipment. Replacement after half a year. Depending on the circumstances.Posarika,The cooking materials and foods refrigerated in the quick-frozen warehouse contain a certain amount of fat, protein and starch. The existence of these nutrients will make molds and bacteria multiply and grow in large numbers. In order to do a good job in the hygienic management of cold areas and ensure the refrigeration quality of food and cooking raw materials, it is necessary to carry out the hygienic disinfection of cold areas regularly.The equipment that needs to be installed in the warehouse and put into the warehouse shall be installed in place or placed in an appropriate position in the warehouse; The wall warehouse board shall be installed from the corner of the warehouse body, and the professional cold warehouse shall be installed. The cold warehouse shall be installed. The cold warehouse shall be constructed. The fruit fresh-keeping cold warehouse and medical cold warehouse shall have high pressure rating, good waterproof performance, fire and high temperature resistance, strong overload capacity, corrosion resistance, radiation protection and long service life. The corner shall be temporarily fixed with . color plate angle steel; When installing each wall panel, evenly apply two layers of foaming material on the joint surface of male and female groove, and apply one layer of foaming material when installing polystyrene wall panel. The blanking shall be uniform and continuous; After the wallboard is installed in place, pull rivets at the lap joint of the internal and external steel plates of the two wallboards for connection and fixation, and the rivet spacing in the warehouse should be mm; When connecting the library plate in the form of eccentric hook connection, the eccentric hook shall be loosened once before installation to ensure reliable locking during installation.These are several very common cold storage materials. The use of these materials has greatly improved the thermal insulation and refrigeration performance of the cold storage, today's various cold storage materials emerge in endlessly, and the cold storage is different from each other. When purchasing, we should make reasonable comparison and select products suitable for our own use needs and economic conditions.