DelmasDesign of cold storageCan you completely isolate radioactive materials
2023-03-18 00:25:42Disadvantages of multi-layer cold storage: the vertical transportation volume of the warehouse is large, and the goods in and out and operation management are not as convenient as single-layer cold storage; With the development of the floor load capacity, large construction equipment is required and the construction period is long.When installing the polyurethane insulation board the foundation construction is complex. High cost; When prefabricated components are used, the adhesion between the panel of the polyurethane insulation board and the thermal insulation material is short and often high.Delmas,Compared with the logistics engineering design of ordinary commodities, so as to maintain the freshness of circulation and prolong the freshness period of fresh food. In recent years,DelmasCold storage company, with the frequent cross regional trade, KFC refrigeration has received more and more demand in the design and construction of logistics refrigeration engineering. What are the basic functions of logistics refrigeration engineering in design?In the process of realizing your dream, you must remove all the influences. It is very important to recognize that when these beautiful refrigerators are built in the villa room, the collection pit (pool) for flushing (thawing) and drainage should adopt the Countermeasures of avoiding freezing and cleaning and avoiding backflow of water.Carnot, the cold storage that only circulates vegetables can only build a fresh-keeping cold storage, while the cold storage with refrigeration + freezing will be built if there are many types of circulating goods and great difference in storage temperature. As for the size of the cold storage, it should be determined according to the type, quantity, frequency, cycle, whether to use shelf stacking and so on. For example, for fruits and vegetables packed in cartons, the storage capacity of -kg per cubic meter can be referred to, and the size of cold storage construction can be estimated in combination with the storage capacity rate of about .-..Cold storage has good fire and flame resistance. After adding flame retardant, polyurethane is a kind of flame retardant and self extinguishing material. If it is burned by fire, it can be carbonized, unlike flow burning and flashover like extruded board, which can effectively prevent fire spread. In particular, it can be closed as a whole after fire prevention treatment to form non combustible products.The quick freezing storehouse of vegetables and fruits is not suitable to use exhaust cooling,DelmasHow much does it cost to install a cold storage, but use fan to supply air for refrigeration, because the gas in the quick freezing storehouse needs to be circulated and dispersed regularly to avoid carbon oxide poisoning caused by high concentration of carbon oxide in local areas. Therefore, in the quick freezing warehouse, the refrigeration equipment needs to be used together with the air conditioning equipment. The selection of refrigeration equipment is different from that of low-temperature freezer and ordinary quick freezing warehouse.
- precautions for floor installation of cold storage: the floor shall be installed flat, the uneven part shall be leveled with materials, and the locking hook between the plates shall be locked to ensure that the warehouse surface is flat without hollow feeling. (note that if this drainage system is installed outdoors in the north, the drainage pipe shall be insulated).When installing and splicing the storeboard in the fresh-keeping storehouse, it needs to be tightly sewn to ensure the tightness; The fresh-keeping storehouse will discharge water during operation, and the drainage pipe should be installed in a place that can circulate; An anti-collision barrier shall be installed around the door of the fresh-keeping storehouse to prevent the door from being damaged by impact. To play an eye-catching role, the fresh-keeping storehouse shall be equipped with emergency lights, alarm devices and safety channels to facilitate self rescue or alarm for help in case of emergencies.How to maintain the refrigeration compressor in the cold storage in order to prolong its service life and reduce the occurrence of faults in the use process. The refrigeration compressor in the cold storage needs regular maintenance. Here we introduce the maintenance of the compressor in the cold storage.Welcome calls ,The cooking materials and foods refrigerated in the quick-frozen warehouse contain a certain amount of fat, protein and starch. The existence of these nutrients will make molds and bacteria multiply and grow in large numbers. In order to do a good job in the hygienic management of cold areas and ensure the refrigeration quality of food and cooking raw materials, it is necessary to carry out the hygienic disinfection of cold areas regularly.Generally, in the actual operation of the refrigeration system, because the temperature conditions are constantly changing, only by relying on the careful operation of the cold storage management personnel and accurately adjusting the operation of the refrigeration equipment of the cold storage, can the refrigeration system always be in the ideal working state and achieve the effect of energy saving.The quick-frozen warehouse is easy to load and unload. All the plates and walls of the quick-frozen warehouse are produced by molds. You can choose tens of millions of products. Professional cold storage installation, installation of cold storage, cold storage construction fruit preservation cold storage, medical cold storage and transaction safety are guaranteed. Through internal concave convex groove connection, loading, unloading and handling are convenient. The installation period is short. Small and medium-sized cold storage can be delivered in - days, The library body can be combined, separated or increased or decreased according to the needs of users.
Frequently observe the operation state of the heart compressor of the cold storage equipment and its exhaust temperature. During the season change operation, pay special attention to the operation state of the system and adjust the liquid supply and condensation temperature of the system in time.install,Kg to kg / m, and the steel plate thickness generally needs to be more than . mm to meet the standard. On the market, the main raw materials of special cold storage board for cold storage project are polyphenylene polyethylene and polyphenylene grease. The density of thermal insulation material foamed by polyphenylene is thin, and the thermal insulation coefficient is not very high; After a certain ratio of polyethylene it can foam cold storage insulation materials with appropriate density and good thermal insulation effect, and has high load-bearing capacity; Polyphenylene resin has strong water absorption, but poor heat insulation. Therefore, the polyurethane board has very good thermal insulation performance and does not absorb moisture.Before the warehouse is fixed with angle aluminum, it shall be sealed with glass glue and fixed with angle aluminum with solid pull Mao. The distance between pull rivets is mm. The distance between the upper and lower sides of the door is mm.The overall construction achievements of the cold storage project have been put into use, and the service life can reach years.Delmas,The three-dimensional automatic cold storage adopts a computer, which can complete the loading, unloading and stacking in the storage, the control of storage temperature and the operation of refrigeration equipment.The factors affecting the installation cost of cold storage are as follows: cold storage construction: the site selection shall comply with laws and regulations and meet the relevant requirements for food hygiene and. And pay attention to protecting the environment and ecological balance. In addition, it shall be conducive to production,DelmasPreparation of vegetable fresh-keeping cold storage, construction and dry ceremony.During the use of cold storage, attention shall be paid to the collision and scratch of the storage body to avoid the depression and corrosion of the storage plate, which will seriously reduce the local thermal insulation performance of the storage body.