RichelieuPreparation of vegetable fresh-keeping cold storageWhat areas can it be applied to
2022-05-28 00:19:28The door of the combined cold storage is not tightly closed. Please adjust the distance between the hinge on the door and the door lock and the storage body.Emergency measures during the use of the medical cold storage project, most medical cold storage projects will be equipped with emergency equipment, so that the medical cold storage project can achieve the effect of normal power supply. Once the automatic temperature or humidity monitoring system is abnormal, the cold storage door should be closed in time, So as not to expose more air conditioners, resulting in corresponding problems in the quality of stored products. The medical cold storage project also has a self rescue system in time. If the temperature of the cold storage exceeds the limit, the system cooling system will also be turned on. When the temperature returns to normal, it will be automatically turned off.Richelieu,Pressure leak test: the pressure leak test of the fresh-keeping warehouse system is the same as that of the sewage blowing working sample, which is required to be carried out by air compressor. If ammonia compressor is used, a special one shall be designated and the exhaust temperature shall be strictly controlled. When high pressure is applied, the method of segmenting and reducing the pressure difference shall be adopted.Thermal insulation rigid polyurethane has low thermal conductivity and good thermal performance. When the density of rigid polyurethane is ~ kg / m, the thermal conductivity is only . ~ .w / (m.k), which is the lowest among all thermal insulation materials at present.Purral, - floor installation of cold storage: first level the floor, then install the floor, select a beautiful floor and put it in a conspicuous place, and do a good job in the floor and evaporator drainage system.Vent valve or water seal well shall be set at the outlet of flushing (thawing) drainage pipeline. Cold proof measures shall be taken for exhaust valves and water sealed wells in severe cold areas.Cold storage has good water tightness. Polyurethane rigid foam has low water absorption, good permeability to water vapor, foam holes, disconnected and closed porosity of more than %. It is a dense microporous foam material, which is more dense than air surface, and is not easy to permeate. It belongs to hydrophobic materials.
Install the electric control system. The electric control system of the cold storage mainly includes electric controller, electric door, lighting and other electrical equipment in the cold storage. The power supply of the cold storage is required to be stable phase line, and the power supply or backup power supply can be used as required. The circuit shall have reasonable discharge and corresponding protective measures.For the selection and preparation of the ground location of the cold storage, such as working intermediates packaging and combing room, special tool warehouse, loading and unloading platform, etc.Reasonably adjust the cold storage evaporator and defrost in time: Generally speaking, every ℃ increase in the evaporation temperature of the cold storage can save energy by ~ . Therefore on the premise of meeting the refrigeration process of the product,RichelieuCold storage of drugs, the liquid supply can be adjusted to increase the evaporation temperature as much as possible.technological innovation,Cold storage has good water tightness. Polyurethane rigid foam has low water absorption good permeability to water vapor, foam holes, disconnected and closed porosity of more than %. It is a dense microporous foam material,RichelieuHow much is the installation cost of small cold storage, which is more dense than air surface, and is not easy to permeate. It belongs to hydrophobic materials.The spacing of pull rivets at inner and outer corners is mm and mm respectively; After the polystyrene library is installed, the wall panel joints shall be evenly sealed and decorated with silicone sealant.The installation of cold storage board is a link of the cold storage installation project. High price cold storage installation of various specifications cold storage installation, fruit preservation cold storage, medical cold storage. Waste merchants, industry, enterprises and power departments are welcome to visit and negotiate! The cold storage body and storage plate include: floor, vertical plate and ceiling plate. The installation of storage plates in different directions and precautions are as follows: enter the construction site, verify the construction situation according to the construction drawings, and then refer to the following specifications.
We must often use insulation board in our life. It's just the structure of the refrigerator, but the refrigerator, as a in the home, still has some use environment. In the market or marine transportation, the environment of cold storage insulation board is not so optimistic. Professional cold storage installation, cold storage installation, cold storage construction, fruit preservation cold storage, medical cold storage quality assurance. During the preferential activities, new and old customers are welcome to consult. The environmental differences inside and outside the cold storage insulation board are very large, because a large number of items need to be insulated, so the temperature in the cold storage is strict. In such cases, the cold storage insulation board will have relevant problems, Let's understand that the water vapor pressure outside the plate warehouse of the lower cold storage is higher than that inside the warehouse, and the penetration of the envelope is carried out from outside to inside all year round. R gas in polyurethane is replaced by air and water vapor to damp polyurethane. Over time, moisture becomes more and more serious,RichelieuQuotation for installation of fresh-keeping cold storage, and even water vapor condensation occurs, resulting in low thermal conductivity and reduced thermal resistance. In order to avoid and delay polyurethane moisture and prolong the service life of the insulation layer, that is, to form a vapor barrier layer.management,The equipment is built according to the application requirements of low-temperature distribution. It is reflected in the following points: a low-temperature hall, a closed platform, an electric sliding refrigerated door, and a platform height conditioning equipment (lifting channel) are built to complete & ldquo; Door to door & rdquo; Type loading and unloading operation has become a symbol of modern cold storage.Vacuum test: after the pressure test of the fresh-keeping storehouse system is qualified, the vacuum leakage test of the fresh-keeping storehouse system can be carried out. The purpose is to improve the air tightness under the vacuum condition of the fresh-keeping warehouse and prepare the conditions for the ammonia filling of the fresh-keeping warehouse system.Judge the operating sound of the compressor and carefully listen to the operating sound of water pump, cooling tower, compressor, fan and other equipment. In case of abnormal sound, timely warranty is required, so as to avoid greater damage to the compressor due to untimely warranty.Richelieu,The refrigeration of cold storage pays more and more attention to the needs of environmental protection and energy saving. Professional projects include: cold storage installation, installation of cold storage, cold storage construction, fruit fresh-keeping cold storage, medical cold storage and other related businesses. Merchants who hope to have this business please consider the wide scale of warehouse temperature control, the selection and placement of cooling equipment and the description of wind speed field, which are suitable for the cold storage needs of a variety of goods. Equipped with perfect storage temperature active detection recording and active control equipment.The service life of polyurethane cold storage insulation material foam is: besides the basic performance of the initial stage of polyurethane foam, the deterioration of foam performance is also a very important index. When the white material is prepared, the surface of some polyester materials can make the foam have better toughness and impact resistance, but it will become brittle after use for a long time in the cold storage, and will no longer resist impact and collision. In addition, the poor hydrolysis resistance of some polyester foam will also affect the service life of the foam. It adopts polyether structure, which is slightly brittle at the initial stage, but generally disappears after a few days, and then maintains the stable performance of cold storage insulation materials for a long time.Floor insulation of small cold storage the structure of small cold storage is usually called surface, that is, the top, wall and ground are made of color steel plate / stainless steel with appropriate thickness of polyurethane and other insulation materials, because the loading and unloading of small cold storage is often handled manually rather than forklift. Of course, if the height of the warehouse is high and the forklift is required for warehousing, loading and unloading, the insulation board is not recommended for ground insulation, but the ground needs to be insulated separately like the ground insulation sample of medium-sized cold storage.