VaregumInstallation and construction of cold storageHow to accelerate marketization and eliminate backward production capacity

2024-04-05 03:04:03
632HP195506591energy55

The drainage at the outlet of the cooling fan, the drainage of the volatile cooler and the road drainage of the refrigerated warehouse storing food or drinks shall not be immediately connected with the sewage and wastewater pipeline system software, but indirect drainage shall be adopted. For the flushing (thawing) water drainage of each layer in the double-layer cold storage, an exhaust valve equipment shall be set in front of the main riser for flushing (thawing) water drainage.A large number of personnel are not allowed to select goods in the warehouse. Close the warehouse door in time. When the warehouse door is opened, pay attention to whether the air curtain is opened or the door curtain is placed properly. Turn off the lights when leaving the warehouse.Varegum, water shortage or insufficient water in water-cooled machines will increase the exhaust temperature of the fresh-keeping warehouse. The condensation pressure is abnormal and the exhaust pressure of the fresh-keeping warehouse decreases.The three-dimensional automatic cold storage adopts a computer, which can complete the loading, unloading and stacking in the storage, the control of storage temperature and the operation of refrigeration equipment.Melnik,The service life of polyurethane cold storage insulation material foam is: besides the basic performance of the initial stage of polyurethane foam, the deterioration of foam performance is also a very important index. When the white material is prepared, the surface of some polyester materials can make the foam have better toughness and impact resistance, but it will become brittle after use for a long time in the cold storage, and will no longer resist impact and collision. In addition, the poor hydrolysis resistance of some polyester foam will also affect the service life of the foam. It adopts polyether structure, which is slightly brittle at the initial stage, but generally disappears after a few days, and then maintains the stable performance of cold storage insulation materials for a long time.Cold storage design steps: selection and preparation of cold storage location. According to the application characteristics, cold storage can be divided into sexual cold storage, retail cold storage and large-scale cold storage. When large-scale cold storage starts to build a planting area with more centralized hand supply, factors such as superior geographical location and contact with the market should also be taken into account. The cold storage should be located in a cool place without sunlight and frequent warm air. Small and medium-sized cold storage should be built in the room. cold storageThe butt joint between the top warehouse plate and the end of the top warehouse plate shall be treated to prevent air leakage and cold running. After all the top warehouse plates are installed, the butt joint shall be filled with foaming material, and the quality of thermal insulation performance cannot be observed before it is really put into use. It is too late to observe the difference between power consumption. In this large number of experimental tests, strict material selection is carried out in order to achieve this goal: using structural amine ether to reduce thermal conductivity and improve thermal insulation effect; Reduce the water content of various raw materials and formulas as much as possible to avoid deterioration of thermal insulation performance caused by water foaming; Polyether: the product of a large processed factory after strict postprocessing is compared with the polyether of small factory without postprocessing. The foam cell has high uniformity of foam pores and thin wall of foam holes, and its heat preservation performance is obviously better than that of ordinary foam with thick wall and big hole. The use of the tasteless amine catalyst can effectively adjust the balance between foaming and gel reaction, so that the interlayer skin of the sprayed coating is thinner, which is beneficial to the performance of the thermal insulation material of the cold storage. Ordinary polyester polyols are not used.The machine room shall be kept clean and well ventilated, and the condenser shall be cleaned and masonry removed regularly to ensure the normal and stable operation of the unit.Panel types of quick freezing warehouse: color plastic steel plate, salted steel plate, stainless steel plate, embossed aluminum, etc.Service first,The butt joint between the top warehouse plate and the end of the top warehouse plate shall be treated to prevent air leakage and cold running. After all the top warehouse plates are installed, the butt joint shall be filled with foaming material, and the mm wide color steel plate shall be sealed at the butt joint with pull riveting.The water tank is designed to be separated from the machine body and is double-layer. It will not drip due to condensation caused by internal and external temperature difference. It can be interlocked with the refrigeration system,VaregumWhich is a good place to install a small cold storage, that is, it will not be humidified during refrigeration to prevent serious frosting of the fan.Polystyrene foam: polystyrene foam is a new type of synthetic thermal insulation material. It is a kind of plastic, light weight strong heat insulation effect and excellent low temperature resistance. However, due to its cold shrinkage, it is not very convenient for installation.


VaregumInstallation and construction of cold storageHow to accelerate marketization and eliminate backward production capacity



Immediate cooling is to install the condenser of the cold storage in the box or building of the cooling equipment, use the volatilization of the refrigerant to immediately cool the air in the air, and use the cold air to cool the objects that need to be cooled. This kind of refrigeration is characterized by faster cooling speed, small heat conduction temperature difference and simple system software, so it is widely used.Sincere service,The machine room of ammonia refrigeration system shall be equipped with exhaust assembly; The exhaust fan shall adopt anti motor. When the power supply is cut off due to unexpected refrigeration, the fresh-keeping warehouse must be maintained on time and scientifically. No matter how good the equipment is, without scientific use and maintenance, the fresh-keeping warehouse also needs to be maintained regularly every year, so as to ensure its stable operation.The installation of top warehouse plate should be carried out alternately with the installation of wall plate,VaregumCold storage compressor installation, and the wall plate should leave a gap for withdrawing construction equipment; During the installation of the top warehouse plate, the end steel sheet at the overlap with the wall plate shall be disconnected for mm to prevent the cold bridge from running cold; Two layers of foaming materials shall be evenly and continuously punched on the joint surface between each top warehouse plate. Rivets shall be pulled and fixed at the internal and external lap joints of the steel plate, and the rivet spacing shall be mm; According to the design drawings, if there are supporting beams, columns and supporting steel frames in the warehouse, the setting out and positioning shall be carried out and accurate and clear marks shall be made according to the requirements of the design drawings; Weld or install the support beam, column, support steel frame, etc., and the welded junction shall be moisture-proof and treated according to the drawing requirements.VaregumBecause polyurethane sheet has excellent thermal insulation performance, it can reduce the thickness of building envelope and increase indoor use area under the same thermal insulation requirements.Wall and floor fixtures shall start at corners. According to the plate layout drawing, transport the two plates at the corner of the required device to the device location. According to the plate beam height and the model of the angle iron for fixing the mushroom head nylon bolt, drill a hole at the corresponding elevation in the middle of the plate width. When drilling, the electric drill should be perpendicular to the plate surface. Put the mushroom head nylon bolt in the hole, tighten the angle iron, and tighten it horizontally,VaregumCold storage installation manufacturer, so as to make the nylon bolt on the surface of the warehouse plate slightly concave. When setting up the wall panels, foam data and other soft data should be laid on the floor slots along with the floor of the storehouse, so as to avoid damaging the storehouse. After the two corner panels are neutrally removed from the floor, the plane position of the wallboard and the verticality of the storehouse should be adjusted in time according to the location of the laying line, and check whether the top elevation of the wallboard can be correct. After the position of the wallboard is correct, weld the angle iron on the plate beam and fix the inner and outer corners. When welding the angle iron parts, the angle iron parts of the warehouse plate shall be covered with a shield to avoid the high temperature of the welding ground baking the warehouse plate and welding slag on the warehouse plate during electric arc welding.Core tip: in the cold storage project only with sufficient cold storage installation skills can we ensure that the cold storage is more energy-saving and power-saving after installation, convenient use and management and long service life.

and is not prone to failure
404 Not Found

404 Not Found


nginx

Related articles

TocoaFrozen preservationSpecial application environment

TocoaFrozen preservationSpecial application environment

Judge the operating sound of the compressor, and carefully listen to the operating sound of water pu...

Santiago atitlandQuotation for installation of low temperature cold storageThe water in the original industry is so deep

Santiago atitlandQuotation for installation of low temperature cold storageThe water in the original industry is so deep

Fault phenomenon: high current or tripping during unit startup, and problems of user air switch; Inp...

Andorra la Vella Medical freezingWorking pressure product specifications and parameters

Andorra la Vella Medical freezingWorking pressure product specifications and parameters

The installation of cold storage board is a link of the cold storage installation project. High pric...

GuadalupeFreezerThe reason why it gets harder and harder

GuadalupeFreezerThe reason why it gets harder and harder

Fault phenomenon: fan motor overload, fan deformation; Fan motor fault; Fan motor thermal relay faul...

PastaviCold storage installation disciplineSolutions to product problems

PastaviCold storage installation disciplineSolutions to product problems

Polyurethane foam foam dimensional stability: cold storage polyurethane foam in severe temperature c...

emotionHow much is it to install a cold storageHow to reduce the fault

emotionHow much is it to install a cold storageHow to reduce the fault

Here we focus on polyurethane. Polyurethane is an ideal cold storage material in the cold storage pr...

评论列表

914HP134131469
2024-04-05 11:54:47

The seller is really good, VaregumInstallation and construction of cold storage is the same as the introduction, honest seller

60HP184127502
2024-04-05 10:22:14

VaregumInstallation and construction of cold storageHow much is the best price, and I will give you a comment, can VaregumInstallation and construction of cold storage be cheaper?

256HP158312377
2024-04-05 10:46:48

Good seller, thank you. My colleagues like VaregumInstallation and construction of cold storage very much. Come again next time!

发表评论    

◎欢迎参与讨论,请在这里发表您的看法、交流您的观点。