HamDouble column aluminum alloy lifting platformTolerance of dimensions

2024-05-04 00:09:53

The basic content of escalator shaft measurement is to measure the lifting height. The same as measuring the height of a straight ladder, strictly speaking, attention should be paid to whether there is a drop between the positioning point of the line drop and the decoration surface of the lower support beam of the ladder.The basic content of escalator shaft measurement is to measure the lifting height. The same as measuring the height of a straight ladder, strictly speaking, the lifting height of a ladder is the vertical distance between the finished ground at the upper and lower support beams. When using the suspension line method to measure, attention should be paid to whether there is a drop between the positioning point of the line drop and the decoration surface of the lower support beam of the ladder.HamAs elevator people, let's talk about elevator and elevator safety knowledge: The elevators we currently use include box type passenger elevators, escalators, and dedicated cargo elevators. Dedicated cargo elevators are installed due to special needs, and we don't use many of them. Now let's take a look at the safety knowledge of box type passenger elevators and escalators: When we take escalators, Be sure to follow the safety instructions when riding on the elevator. Do not crowd or play around, hold onto the elevator firmly, fasten your shoelaces, and avoid getting them caught up.b. When the old elevator cannot start: due to the inability to enter the shaft, limited data can only be obtained from outside the shaft to determine whether it is non-standard (if there is a high platform in the machine room, the plane size of the shaft can be measured in the machine room, but it is not accurate enough) for elevator quotation negotiation reference. In this case,HamPrice of Small Household Sightseeing Elevator, the signing of the contract should state that the shaft rectification and costs are the responsibility of the user. For uncertain shaft structures and dimensions, users should be reminded to provide them to the elevator after the old elevator or notify the elevator to take measurements before the new elevator is put into operation.Pontevedra,The front room of the fire elevator is equipped with Class B fireproof doors or fireproof rolling shutters with stopping function.If the elevator is already on the first floor, immediately open the elevator door and enter the firefighter's dedicated state.There is a dedicated fire telephone in the fire elevator car.


HamDouble column aluminum alloy lifting platformTolerance of dimensions



The safety monitoring machine room environment screen cabinet main power switch traction wheel speed limiter shaft and pit guide rail layer door and car counterweight should be reliably fixed with pressure plates to prevent loosening.When passengers are riding on the escalator,HamStage style lifting platform, they may lose their balance and fall due to leaning against the skirt board on the side of the escalator, which does not move, it is more likely to fall on the escalator due to the inability to hold the handrail properly. So, when riding on the escalator, we must stand firmly and support it well, and do not lean against the skirt board on the side of the escalator.If the elevator is in a downward direction, and automatically open the elevator door.production,Restore the command button function in the cabin for firefighters to operate.Electrical components are roughly divided into screens, electrical switches for each safety circuit, etc. It is the brain of the elevator and the central nervous system of the elevator. The movement, operation, so it must be treated as a top priority in daily maintenance work. Do not short circuit the elevator circuit inside the screen during work. When the elevator door system malfunctions, someone shorts the elevator door for convenience in order to find the fault. This is very dangerous, and there are many accidents when shorting the door. Why? If a person opens the hall door and extends their head inward, the elevator happens to run up or down to this point, and the hall door is shorted, the elevator cannot stop, so an accident is highly likely to occur. So in our daily maintenance work, we must not short-circuit the safety circuit. If it is necessary to short-circuit, we must identify which safety component has a problem and which safety component needs to be shorted. Moreover, after maintenance or urgent repairs are completed, we must promptly remove the short-circuit wire. Professional household elevator manufacturer, with a large quantity and excellent quality at a reasonable price. It is fire-resistant, waterproof, high-temperature resistant, sturdy and durable, safe and reliableThe beam edge distance is too small: The method of shortening the lower platform is to shorten the total length of the escalator, but note that the range of shortening is very limited, generally not exceeding mm. Generally, the platform cannot be shortened because it contains equipment such as cabinets and motors. Change the angle of the escalator from degrees to degrees


HamDouble column aluminum alloy lifting platformTolerance of dimensions



The shaft for updating the old elevator: The measurement of the shaft for the old elevator is the same as the shaft that has just been constructed. When the old elevator is not yet in use, try to obtain relevant data outside the shaft, such as the size of the machine room, floor height, and net size of the door opening. There are two situations when the old elevator is not yet in use: a. When the old elevator can start: in this case, the elevator technician must cooperate in measuring the shaft! And be sure to pay attention to safety! The elevator technician opens the hall door on the first floor and initiates maintenance operations to drive the car above the second floor. The measurement personnel open the floor door on the first floor to measure the pit data, paying attention to recording the pit size and the wall structure of the first floor, such as whether the hall door is centered, whether there are brackets, whether there are special structures on the shaft wall, the spacing between ring beams, and the position of embedded parts. Then, the measuring personnel and elevator technicians take the elevator to the top floor. After measuring the machine room, the measuring personnel, with the cooperation of the technicians, go up to the car roof and start the elevator at a maintenance speed. When the car roof is slightly lower than the sill of the second floor hall door, the parking lot stops. During this process, the measuring personnel observe and measure the full travel of the shaft from the top floor, mainly the height of the floor, while recording the measurement (safety must be paid attention to, and special attention should be paid to moving parts such as counterweights and wire ropes).quality index, width, and depth of the pit (if any), and observe whether there are grooves and embedded parts at the support beam.Elevator Tip : Why elevators can trap people? Every elevator door on each floor has a safety switch, which can trigger the elevator to shut down in case of any abnormality. The elevator getting stuck is actually when the system detects an abnormal signal and triggers a protective device, like braking to stop.The front room of the fire elevator is equipped with Class B fireproof doors or fireproof rolling shutters with stopping function.Ham,b. When the old elevator cannot start: due to the inability to enter the shaft, the plane size of the shaft can be measured in the machine room, but it is not accurate enough) for elevator quotation negotiation reference. In this case, the signing of the contract should state that the shaft rectification and costs are the responsibility of the user. For uncertain shaft structures and dimensions, users should be reminded to provide them to the elevator after the old elevator or notify the elevator to take measurements before the new elevator is put into operation.The mechanical components of the elevator's traction machine require oil. There are two scales on the outer cover of the traction machine. Open the oil nozzle to check that the oil should be in the middle of the two scales. If the oil is lower than the lower scale, it means that the traction machine should be refueled. If not refueled, the elevator will not operate well for a long time, leading to the burning of the elevator traction machine and motor. After the elevator has been running for a long time, the oil should be replaced in a timely manner to keep the traction machine clean and in good condition.  “& rdquo; Elevator shaft: The design conditions are provided by the user to the architectural design department. The architectural design department analyzes whether the on-site pit depth top floor height,HamRear flip hydraulic flipper, as well as which building structures are needed (such as smashing stairs or floors) etc. can meet the installation requirements of the elevator reaction force, and develops a renovation construction plan. If it is indeed necessary to change the elevator structure due to civil engineering conditions (such as car size, door opening width, etc.), then consider the non-standard design of the elevator.


404 Not Found

404 Not Found


nginx

Related articles

Lorient Boarding axle hydraulic mobile typeLife impact

Lorient Boarding axle hydraulic mobile typeLife impact

  . Platform side boarding bridge: The platform side boarding bridge is directly installed at the fr...

KlagenfurtSingle suction slurry pumpWhat are the functions of processing machinery

KlagenfurtSingle suction slurry pumpWhat are the functions of processing machinery

  Water or air leakage in the pipeline. The nut may not be tightened during installation. If the lea...

GonaifSubmersible sewage pumpReasons why the spot cannot be followed up

GonaifSubmersible sewage pumpReasons why the spot cannot be followed up

  Screw it down, and then remove the bearing inner race, O-ring,  The course can be stronger.  With...

southern suburbsFixed hydraulic boarding axleVisualization technology

southern suburbsFixed hydraulic boarding axleVisualization technology

During the application process of hydraulic boarding bridges, it is necessary to follow the operatin...

XinqiuElectro hydraulic lifting platformFactors prone to stomata

XinqiuElectro hydraulic lifting platformFactors prone to stomata

Fixed lifting platforms with strong load-bearing capacity usually occupy a large amount of space. If...

PapenderchtFully automatic hydraulic lifting platformWhat to pay attention to when using

PapenderchtFully automatic hydraulic lifting platformWhat to pay attention to when using

Working at heights is a common practice nowadays, but it also has a certain degree of danger. So peo...

评论列表

258HP138990173
2024-05-04 08:56:50

You HamDouble column aluminum alloy lifting platform are okay, give a discount next time you buy, and buy your company's HamDouble column aluminum alloy lifting platform