EnantiomerHow much is the cold storageSpot inventory resources
2022-08-17 03:02:29The refrigerator compressor unit generally adopts high-end units with guaranteed quality and strong operation stability. The evaporator adopts the imported joint venture refrigeration air-cooled evaporator, which can effectively meet the refrigeration capacity of the refrigerator and ensure the refrigeration effect of the refrigerator. The refrigerator lamp adopts the special LED energy-saving lamp for the refrigerator, which has the advantages of low temperature resistance, low energy consumption and long service time, It can effectively save the operation cost of cold storage.Before fastening all sodium nuts and lock nuts of the refrigeration system, apply refrigerant oil to strengthen the tightness. Clean after fastening. The packing of each cut-off door shall be locked.Generally, in the actual operation of the refrigeration system, because the temperature conditions are constantly changing, only by relying on the careful operation of the cold storage management personnel and accurately adjusting the operation of the refrigeration equipment of the cold storage, can the refrigeration system always be in the ideal working state and achieve the effect of energy saving.Where is it,The lights in the warehouse are not on. Please check whether the switch fails and whether the bulb is damaged. Cut off the power supply when installing the lampshade, and pay attention to the waterproof of the lamp.More and more people begin to build cold storage, and most people choose to use cold storage for cold storage construction. Why? Why do people choose cold storage for construction? What are the advantages of cold storage? The following is a detailed introduction.Fire retardant, flame retardant and high temperature resistant polyurethane is a kind of flame retardant self extinguishing material after adding flame retardant. Its softening point can reach more than ℃, and it will decompose only at higher temperature. In addition, polyurethane forms carbon deposits on the surface of the foam, which helps to isolate the foam below. It can effectively prevent flame spread.
Because polyurethane sheet has excellent thermal insulation performance, it can reduce the thickness of building envelope and increase indoor use area under the same thermal insulation requirements.Recommendation and consultation,The construction of small cold storage is widely used in life, such as food industry, manufacturing industry, etc. since cold storage is so widely used,EnantiomerPreservation of fruits in cold storage, do you know cold storage? Especially the construction process and steps of cold storage. Understanding the construction process and steps of cold storage is helpful for all links of cold storage maintenance.The selection of thermal insulation material is important to the quality of controlled atmosphere storage; The selection of thermal insulation materials for the controlled atmosphere storage must be adjusted to local conditions, which should not only have good thermal insulation performance but also be economical and practical. The thermal insulation materials are divided into several types. One is the plate processed into fixed shape and specification, with fixed length, width and thickness. The plate of corresponding specification can be selected according to the installation needs of the controlled atmosphere storage. The cm thick plate is generally selected for the medium temperature controlled atmosphere storage, cm or cm thick plates are generally selected for low-temperature controlled atmosphere storage and frozen controlled atmosphere storage. The other can be sprayed with polyurethane for foaming, and the materials can be directly sprayed into the built brick or concrete warehouse. After setting it is moisture-proof and heat-insulating. The heat-insulating material plates include polyurethane, polyphenylene grease, installation, construction, but the cost is low. The structure of modern controlled atmosphere storage is developing towards assembly, and the storage components including moisture-proof layer and thermal insulation layer are made to achieve on-site assembly. The point is that the construction is convenient, but the cost is relatively high.The installation of top warehouse plate should be carried out alternately with the installation of wall plate, and the wall plate should leave a gap for withdrawing construction equipment; During the installation of the top warehouse plate, the end steel sheet at the overlap with the wall plate shall be disconnected for mm to prevent the cold bridge from running cold; Two layers of foaming materials shall be evenly and continuously punched on the joint surface between each top warehouse plate. Rivets shall be pulled and fixed at the internal and external lap joints of the steel plate, and the rivet spacing shall be mm; According to the design drawings, if there are supporting beams columns and supporting steel frames in the warehouse, the setting out and positioning shall be carried out and accurate and clear marks shall be made according to the requirements of the design drawings; Weld or install the support beam, column,EnantiomerCold storage installation company installation, support steel frame, etc., and the welded junction shall be moisture-proof and treated according to the drawing requirements.Enantiomer,The service life of the cold storage depends on the quality of the refrigeration equipment, but it also has a great relationship with the proper daily management and maintenance after the installation of the cold storage. Many times, people often ignore the latter point. In daily life, as long as we maintain and maintain the cold storage regularly, we can greatly improve the service life of the cold storage and reduce the cost.Disadvantages of multi-layer cold storage: the vertical transportation volume of the warehouse is large, and the goods in and out and operation management are not as convenient as single-layer cold storage; With the development of the floor load capacity, the floor area ratio of each cold room is low; When the multi-storey cold storage is built on the foundation with poor ground resistance, the foundation construction is complex. High cost; When prefabricated components are used, large construction equipment is required and the construction period is long.Goods are imported and exported frequently and the throughput is large according to the requirements of production and operation