LidaHow much is the cold storage installed per square meterHow does it work
2024-03-01 03:49:23Thermal insulation rigid polyurethane has low thermal conductivity and good thermal performance. When the density of rigid polyurethane is ~ kg / m, the thermal conductivity is only . ~ .w / (m.k), which is the lowest among all thermal insulation materials at present.Polyurethane foam foam dimensional stability: cold storage polyurethane foam in severe temperature changes or at a relatively low temperature will appear dimensional changes (as contraction), the size changes often reflect bubble cracking or falling off, and these will inevitably affect the normal use of cold storage. In addition to regular simulation of performance testing, more emphasis is placed on the selection of high quality materials: special energy polyether compound use, so that the foam body mesh structure,LidaHow much is the cold storage, greatly improving the foam low temperature resistance. At present polyether commonly used in spraying materials contains a large number of functional components, and a large number of linear structures formed after reaction are difficult to be stable at low temperature; The use of the energy crosslinking agent also greatly improved the dimensional stability of the foam. The selected polyether adopts catalysis in the production stage, and the reaction is complete, so that the polyether maintains a high reaction rate (that is, it can react completely with black material); Some manufacturers in order to achieve foam appearance does not produce deformation phenomenon and add a hole component to foam material, reduce the bubble closed hole rate, achieve the effect of stable size, but it has sacrificed the thermal insulation performance of polyurethane cold storage insulation material foam.Lida,The ground should be flat and not uneven. If the ground is uneven, the ground of the warehouse must be leveled before the cold storage can be built and installed.The common phenomenon of quick freezing storehouse is that the temperature of quick freezing storehouse can't drop down or drops slowly. Now, a simple analysis is made on the reasons for the slow drop of temperature: the cold capacity loss of quick freezing storehouse is large due to poor thermal insulation or sealing performance; the poor thermal insulation performance is due to insufficient thickness of thermal insulation layer of pipeline and warehouse thermal insulation wall, resulting in poor thermal insulation and thermal insulation effect It is mainly caused by improper selection of insulation layer thickness in design or poor quality of insulation materials in construction.Burton on Trent,The machine room of ammonia refrigeration system shall be equipped with exhaust assembly; The exhaust fan shall adopt anti motor. When the power supply is cut off due to unexpected refrigeration, it shall be able to ensure the reliable power supply of the exhaust fan. The overload protection of the exhaust fan should be applied to the signal alarm system without directly stopping the exhaust fan. The button box of the exhaust fan shall be concealed in the wall outside the ammonia compressor room.The quick freezing storehouse of vegetables and fruits is not suitable to use exhaust cooling, but use fan to supply air for refrigeration because the gas in the quick freezing storehouse needs to be circulated and dispersed regularly to avoid carbon oxide poisoning caused by high concentration of carbon oxide in local areas. Therefore, in the quick freezing warehouse, the refrigeration equipment needs to be used together with the air conditioning equipment. The selection of refrigeration equipment is different from that of low-temperature freezer and ordinary quick freezing warehouse.The foundation of cold storage is affected by low temperature, and the water in the soil is easy to be frozen. Due to the volume of frozen soil, the ground will be broken and the whole building structure will be deformed. If the damage is serious, it may even make the cold storage unusable. Therefore, in addition to the thermal insulation layer, unloading and transportation machinery and equipment. Therefore, the structure of the cold storage plate shall be firm and have large bearing capacity. In low temperature environment, especially in the process of periodic freezing and thawing cycle, building structures are vulnerable to. Therefore, the structure of each part of the cold storage and the building materials of the cold storage should have sufficient frost resistance.
The door of the combined cold storage is not tightly closed. Please adjust the distance between the hinge on the door and the door lock and the storage body.Precautions for fruit delivery: it is the same as warehousing. It should be gradually adapted during delivery to avoid condensation on the fruit surface, dark color, affecting the taste and causing decay. The temperature should be ~ ℃ higher than the fruit temperature each time, and the relative humidity should be % ~ %, When the temperature rises to ~ ℃ different from the external temperature, it can be delivered from the warehouse.Reasonably adjust the cold storage evaporator and defrost in time: Generally speaking, every ℃ increase in the evaporation temperature of the cold storage can save energy by ~ . Therefore, on the premise of meeting the refrigeration process of the product,LidaCold storage installation, the liquid supply can be adjusted to increase the evaporation temperature as much as possible.Fair price,Fault phenomenon: fan motor overload, fan deformation; Fan motor fault; Fan motor thermal relay fault (aging); Loose wiring; Cooler blocked; Large exhaust resistance. Cold storage fault phenomenon: dryer does not operate, compressor line is disconnected, thermal relay acts, high voltage switch acts, compressor is locked, line is falsely connected or loose fault phenomenon: it stops in a short time after drying, ambient temperature is too high, condenser is blockedProper protective measures shall be taken during transportation to prevent plate from being strangled and scratched.Artificial refrigeration keeps the room at a constant temperature. The walls, floors and flat roofs of large cold storages are laid with thermal insulation materials with a certain thickness to reduce the incoming heat from the outside. In order to reduce the absorption of solar radiation, the surface of the external wall of the cold storage is painted white or light color.
Step of cold storage design: selection and laying of cold storage thermal insulation materials. The use of cold storage thermal insulation materials must be adjusted to the time, which not only has excellent fire resistance, but also has high cost performance. There are several types of cold storage insulation materials. One is the plate produced and processed into a fixed shape and specification, with fixed length, total width and thickness. The cold storage plate with relative specification and model can be selected according to the installation of the warehouse body. The high and medium temperature cold storage generally adopts cm thick cold storage plate, cm or cm thick cold storage board is generally used for ultra-low temperature cold storage and freeze-cleaning cold storage; Another kind of cold storage can be sprayed with polyurethane spray paint and polyurethane foam, and the raw materials can be sprayed into the brick or concrete warehouse of the cold storage to be built immediately. After shaping, it is both waterproof and thermal insulation. Thermal insulation materials include polyurethane, polystyrene grease, etc. Polyurethane is non hygroscopic and has good fire resistance, but the cost is high; Polystyrene resin has strong water absorption capacity and weak fire resistance, but the cost is low.Production department,Installation of unit electrical box: the unit electrical box shall be installed near the unit; Vertical installation. If the unit is installed on the top of the warehouse, the distance between the box bottom and the top of the warehouse must be & amp; gt; mm; The electrical box can be fixed on the building wall or on the angle steel frame.Does the unit location meet the relevant conditions? Whether the heat dissipation and pipe length can meet the requirements.Installation of unit electrical box: the unit electrical box shall be installed near the unit; Vertical installation. If the unit is installed on the top of the warehouse the distance between the box bottom and the top of the warehouse must be & amp; gt; mm; The electrical box can be fixed on the building wall or on the angle steel frame.Lida,Secondly, since the cooling of the compressor is not continuous, the multi work operation at night can be selected if possible. When working at night, the cooling water temperature is reduced, and the condensation pressure and condensation temperature are reduced. The cooling capacity of the sampling system, coupled with the equal role of the cold storage board,LidaInstallation of small fresh-keeping storehouse, reduces the power operation of the compressor and achieves the purpose of energy saving.Indirect cooling is that the air in the warehouse is pumped into the air cooling device by the blower. The air is absorbed by the evaporation pipe circling in the cooling device and then sent to the warehouse for cooling. The advantages of air cooling are rapid cooling, uniform temperature in the warehouse, and can bring harmful gases such as carbon oxide out of the warehouse during storage.The selection of cold storage is very important for cold storage, because cold storage is different from ordinary cold storage. The temperature in cold storage is usually low, and the air temperature, humidity and environmental requirements are relatively high. When selecting cold storage, the temperature in the cold storage is difficult to, which is easy to cause the deterioration of products in the cold storage, wasting more resources and increasing the cost.