La PazCold storage manufacturer installationHow to handle after analysis

2024-01-05 01:12:59
632HP195506591energy83

In fact, there are some unique installation skills when installing the cold storage? The cold storage installed according to these skills is often short in both effect and quality, and the specific installation skills of the cold storage will also make some relatively detailed introduction for you in the following article. When installing the cold storage you should install it from the corner first. Later, according to the height of the cold storage, make a hole in the middle of the insulation board, and tighten the angle iron parts until there is a hole on the insulation boardThe refrigeration equipment in the fresh-keeping environment of the quick-frozen warehouse mostly adopts the single-stage compression refrigeration system, with freon as the refrigerant. The evaporation mode in the warehouse is the cooling fan, which can be ceiling type. If the number of warehouses is small and the volume does not exceed cubic meters, the refrigeration mode of the warehouse machine can be considered. If there are a large number of warehouses, the mode of multiple heads in parallel can be considered.La PazSystem blowdown: it is easy to use the standby air compressor. When the air compressor cannot solve the problem, it can be replaced by ammonia compressor, but the exhaust temperature during use shall not exceed ℃, otherwise the oil viscosity will be reduced beyond the flash point and carbon will be formed, thus damaging parts and components.The construction structure of structural cold storage can be brick concrete structure or steel structure,La PazLarge and medium-sized cold storage installation company, which can be determined according to their own budget and actual needs. At present,La PazInstallation of cold storage, most cold storages are constructed with single-layer steel structure and are equipped with combined thermal insulation storage body, refrigeration system, system, etc. according to the actual needs of cold storage circulation.Orhei, the heat transfer effect will be reduced: once more refrigerant oil is attached to the inner surface of the evaporator heat transfer tube, the heat transfer coefficient will be reduced. Similarly,La PazInstall a cold storage installation, if there is more air in the heat transfer tube, the heat exchange area of the evaporator will be reduced, the heat transfer efficiency will be significantly reduced, and the decline rate of warehouse temperature will be slowed down.Reasonable space: the power consumption of the cold storage is calculated according to the cold consumption of the cold storage, which usually includes two parts: the cold consumption during cargo cooling and refrigeration; It is the cooling consumption of the refrigeration room itself and operation management.Anti odor floor drain shall be set on the pavement of refrigeration room and refrigeration unit room, and the height width ratio of floor drain water seal shall not be less than mm. The elevator shaft, electronic pit and other places convenient for drainage shall be provided with drainage and equipment to avoid backflow of water.


La PazCold storage manufacturer installationHow to handle after analysis



For water-cooled units, the turbidity of cooling water shall be frequently, the cooling water shall be replaced frequently, and whether the running, emitting, dripping, leakage and other conditions of the water supply system exist.If the controlled atmosphere storage is not used for a long time, does it also require refrigeration? If the controlled atmosphere storage is not used for a long time after installation, it does not need refrigeration operation as long as it does not show fluorine leakage. However, there may be fluorine leakage due to long-term non use, so refrigeration operation should be carried out at this time.. Maintenance of food cold storage. In a position convenient for operation outside the door of the refrigerator room a main switch for cutting off the power supply of the refrigeration compressor shall be set. This switch shall be able to stop the operation of the refrigeration compressor, and relevant signs shall be set. If the mechanical panel is set in the main room, a button switch shall be added next to each refrigeration compressor.Scheme customization,During installation, the plates shall be handled with care. Rough operation is strictly prohibited. Burrs shall be removed at the cutting opening to prevent scratching the plate surface and workers.Cold storage design step: the selection of cold storage refrigeration system the selection of cold storage refrigeration system is mainly the use of cold storage refrigeration compressor and air conditioning evaporator. Generally, small and medium-sized refrigerators are dominated by fully enclosed refrigeration compressors. Due to the small output power of the fully enclosed refrigeration compressor, ammonia refrigeration unit can also be considered. Because the output power of ammonia refrigeration unit is large and can be used for machine use, but the installation and management of refrigerated warehouses are cumbersome. When using the air-conditioning evaporator the high-temperature cold storage uses the industrial cold fan as the air-conditioning evaporator. Its characteristic is that the temperature reduction speed is faster, but it is easy to lead to the water consumption of the cold collection; Medium and ultra-low temperature refrigerators are dominated by seamless evaporation pipe slots, which is characterized by very good temperature control effect and moderate cold storage.The construction of cold storage in site selection bears the circulation of low-temperature goods. Therefore, the transportation convenience of cold storage construction site should be given priority in site selection, such as proximity to roads, railways, etc. At the same time, the location of the cold storage should avoid large pollution sources and direct sunlight, and the construction of the cold storage should have good drainage and ventilation conditions.


La PazCold storage manufacturer installationHow to handle after analysis



The selection of equipment for the construction of equipment cold storage is closely related to the size, type and budget of the cold storage.Discount,Thermal insulation rigid polyurethane has low thermal conductivity and good thermal performance. When the density of rigid polyurethane is ~ kg / m, the thermal conductivity is only . ~ .w / (m.k), which is the lowest among all thermal insulation materials at present.The machine room shall be equipped with oxygen respirator, gas mask, gas clothing, rubber gloves, wooden stopper, pipe clamp, acid beverage and other necessary protective and rescue articles, which shall be set in a convenient location, managed by a specially assigned person and used regularly. Relevant personnel shall skillfully master the use of oxygen respirator and personnel rescue.Install the library body. Generally, the warehouse body can be divided into small warehouse body and large warehouse body. The small warehouse body is basically a combined cold storage assembled with warehouse plate. The large warehouse body is mostly a civil cold storage. The assembled or constructed warehouse body is generally required to be flat, compact and solid, without hollow feeling, load-bearing, antifreeze, etc.La Paz,Fire retardant, flame retardant and high temperature resistant polyurethane is a kind of flame retardant self extinguishing material after adding flame retardant. Its softening point can reach more than ℃, and it will decompose only at higher temperature. In addition, polyurethane forms carbon deposits on the surface of the foam, which helps to isolate the foam below. It can effectively prevent flame spread.There are two kinds of refrigeration in the cold storage group: immediate refrigeration and simple refrigeration.In order to prevent damage to the cold storage, it is necessary to lay some foam on the floor of the cold storage tank.

404 Not Found

404 Not Found


nginx

Related articles

La PazCold storage manufacturer installationCommon sense of product selection

La PazCold storage manufacturer installationCommon sense of product selection

For the ground insulation of large cold storage, we can that the ground insulation of medium-sized c...

评论列表

605HP153695373
2024-01-05 09:52:41

I'm quite satisfied, and the quality and workmanship are even worse. Look back and introduce to friends

466HP159575805
2024-01-05 09:24:15

Let me talk about the quality of the goods first: La PazCold storage manufacturer installation Overall it is good, and the packaging is tight. Let’s talk about business services: Like it. Last review express: delivery is fast. The other is to thank the store for discounts, after all, cheap and good products are more real. I hope that the store will give more discounts and notify old customers in time to promote repurchase. I wish business prosperous.

122HP117294921
2024-01-05 08:25:10

La PazCold storage manufacturer installation The quality is very good, I bought it for the second time, the goods are good, the boss is very good

发表评论    

◎欢迎参与讨论,请在这里发表您的看法、交流您的观点。