Pete pointInstallation of industrial cold storagewholesaler
2023-02-18 00:27:19For water-cooled units, the turbidity of cooling water shall be frequently, the cooling water shall be replaced frequently, and whether the running, emitting, dripping, leakage and other conditions of the water supply system exist.The construction structure of structural cold storage can be brick concrete structure or steel structure, which can be determined according to their own budget and actual needs. At present, most cold storages are constructed with single-layer steel structure, and are equipped with combined thermal insulation storage body, unloading platform, refrigeration system, system, pipeline system, etc. according to the actual needs of cold storage circulation.Pete point, and the pipe orifice shall be sealed and wrapped with adhesive tape.Drainage measures shall be provided for the villa room and overhead layer of the road surface of the cold storage engineering building.Kayanza,Pete pointWhere is the cold storage installed,Operating the unit: regularly observe the oil level and oil return of the compressor and the cleanliness of the oil. If the oil is dirty or the oil level drops, it shall be solved in time to avoid adverse effects.Anti odor floor drain shall be set on the pavement of refrigeration room and refrigeration unit room, and the height width ratio of floor drain water seal shall not be less than mm. The elevator shaft, electronic pit and other places convenient for drainage shall be provided with drainage and equipment to avoid backflow of water.The common phenomenon of quick freezing storehouse is that the temperature of quick freezing storehouse can't drop down or drops slowly. Now, a simple analysis is made on the reasons for the slow drop of temperature: the cold capacity loss of quick freezing storehouse is large due to poor thermal insulation or sealing performance; the poor thermal insulation performance is due to insufficient thickness of thermal insulation layer of pipeline and warehouse thermal insulation wall, resulting in poor thermal insulation and thermal insulation effect, It is mainly caused by improper selection of insulation layer thickness in design or poor quality of insulation materials in construction.
Polystyrene foam: polystyrene foam is a new type of synthetic thermal insulation material. It is a kind of plastic, with small density, strong heat insulation effect and excellent low temperature resistance. However, it is not very convenient for installation.The suction pressure of fresh-keeping storehouse remains unchanged, and when the exhaust pressure increases, the exhaust temperature increases; If the exhaust pressure remains unchanged,Pete pointHow much is it to install a cold storage, when the suction pressure decreases, the exhaust temperature also increases. Both cases are caused by the increase of compression ratio of fresh-keeping warehouse. Too high condensation temperature and exhaust temperature of fresh-keeping warehouse are unfavorable to the operation of compressor, which should be prevented. Too high exhaust temperature will dilute the oil and even carbonize and coke, which will worsen the compressor conditions of the fresh-keeping warehouse.Core tip: in the cold storage project, only with sufficient cold storage installation skills can we ensure that the cold storage is more energy-saving and power-saving after installation, convenient use and management and long service life.Installation requirements,The product shade warehouse is a warehouse location below ℃ and the sun cannot be straight. The humidity is % ~ % relative humidity, and there are corresponding strict requirements for the wall ceiling, ventilation, disinfection and epidemic prevention of the warehouse. The refrigeration system adopts full-automatic microcomputer electrical technology and does not need to be on duty. It mainly stores western and Chinese grass materials and instruments, and can monitor and record the temperature and humidity in the storage area.Refrigeration system: refrigeration system is the core part of cold storage design. It is the key to determine the economy environmental protection and performance of cold storage.Indirect cooling is that the air in the warehouse is pumped into the air cooling device by the blower. The air is absorbed by the evaporation pipe circling in the cooling device, and then sent to the warehouse for cooling. The advantages of air cooling are rapid cooling, uniform temperature in the warehouse, and can bring harmful gases such as carbon oxide out of the warehouse during storage.
In the cold storage project, the selection of cold storage is related to the overall operation of cold storage in the future. The selection of high-quality cold storage is conducive to the use and maintenance of cold storage. This requires us to inquire more about the warehouse board for cold storage engineering. Before the construction of cold storage project, we should first realize the temperature requirements of cold storage and the importance of cold storage to cold storage. Because the cold storage project has high environmental requirements such as temperature,Pete pointCold storage construction and installation company, attention should be paid to the performance and material of the cold storage board when selecting the cold storage board.Potential development,When outdoor air enters the cold storage body, it will not only increase the cold consumption of the cold storage, but also bring water into the warehouse. The condensation of water will lead to the building structure, especially the heat insulation structure, being damaged by moisture and freezing. Therefore, a moisture-proof and heat insulation layer should be set to keep the cold storage board building moisture-proof and air-proof performance and good sealing.Ammonia filling leak test: ammonia filling leak detection can be carried out after system blowdown and pressure leak test. The purpose is to improve the air tightness of the fresh-keeping warehouse system and lay a good foundation for the system to fill ammonia and wrap thermal insulation materials.Danfoss thermal valve is adopted for the thermal valve of the cold storage, with guaranteed quality; Due to the high temperature requirements of the cold storage and the high degree of automation and regulation of the temperature, the temperature system of the cold storage adopts microcomputer full-automatic, does not need special people to operate, and can be remotely controlled. When the temperature exceeds the specified range, it will automatically alarm, which is of great significance to the proper preservation of the cold storage.Pete point,Moreover, polyurethane does not produce harmful gas at high temperature.Watertight polyurethane rigid foam has low water absorption, good permeability to water vapor and state of foam pores. It is not connected with each other, and the obturator rate is more than %. It is a dense microporous foam material, which is more dense than the surface of the air, and is not easy to permeate. It is an hydrophobic material.Floor insulation of small cold storage the structure of small cold storage is usually called surface, that is, the top, wall and ground are made of color steel plate / stainless steel with appropriate thickness of polyurethane and other insulation materials, because the loading and unloading of small cold storage is often handled manually rather than forklift. Of course, if the height of the warehouse is high and the forklift is required for warehousing, loading and unloading, the insulation board is not recommended for ground insulation but the ground needs to be insulated separately like the ground insulation sample of medium-sized cold storage.