St. ClaudeDesign cold storage installationIf you don't take good care of it, something will happen
2023-02-20 09:28:19The water tank is designed to be separated from the machine body and is double-layer. It will not drip due to condensation caused by internal and external temperature difference. It can be interlocked with the refrigeration system, that is, it will not be humidified during refrigeration to prevent serious frosting of the fan.Operating the unit: regularly observe the oil level and oil return of the compressor and the cleanliness of the oil. If the oil is dirty or the oil level drops, it shall be solved in time to avoid adverse effects.St. Claude,Once there are impurities in the controlled atmosphere storage system it will affect the sealing performance of suction and exhaust valve plates and valve seats, which will seriously affect the refrigeration capacity of the controlled atmosphere storage.The closed cell structure and surface material of polyurethane rigid foam with good moisture-proof, waterproof and corrosion resistance make it have better air resistance and water vapor resistance, and it can be made into inlaid connection structure during forming, which is easy to assemble. It does not need additional insulating layer to prevent moisture and saves a lot of trouble in laying insulating layer.Petrosani,The cooking materials and foods refrigerated in the quick-frozen warehouse contain a certain amount of fat, protein and starch. The existence of these nutrients will make molds and bacteria multiply and grow in large numbers. In order to do a good job in the hygienic management of cold areas and ensure the refrigeration quality of food and cooking raw materials, it is necessary to carry out the hygienic disinfection of cold areas regularly.Pay attention to the energy saving of the lighting system: the lighting of the cold storage should be considered comprehensively according to the area, science and rationality from the perspective of energy saving and environmental protection. The lighting in the cold storage is concentrated in the working area.According to the size and nature of the cold storage area and in combination with local regulations, the construction form of food cold storage warehouse is to determine the plane layout based on the site, whether it is a single-layer or double-layer warehouse, and the structure is the selection of steel structure or reinforcement solidification. Cold storage capacity, production process, refrigeration, product stacking, temperature, etc. are used to determine the size and location of the cold storage room, so that it can become a whole.
Before the acceptance and delivery of the project, the board surface shall be wiped clean. If there is any scratch, it shall be treated. There shall be no obvious scratch on the board surface.The air conditioning warehouse is equipped with standby power supply. After eliminating the line and load problems, it is the maintenance of external irresistible power lines. If the refrigerated goods in the air conditioning warehouse are expensive or vulnerable to temperature changes, it can be considered to equip the air conditioning warehouse with standby power supply to ensure the operation of refrigeration equipment in the cold storage in a short time after power failure. Large air conditioning warehouses can be considered to be equipped with generator sets, Automatically switch the generator set for power generation after power failure for use. For example,St. ClaudeDesign and installation of fruit and vegetable cold storage,A large number of personnel are not allowed to select goods in the warehouse. Close the warehouse door in time. When the warehouse door is opened, pay attention to whether the air curtain is opened or the door curtain is placed properly. Turn off the lights when leaving the warehouse.During the cold storage commissioning, special personnel shall be assigned to ensure that the surface of the cold storage plate shall reflect evenly without condensation and cold running; Sealing conditions of joints and holes; Whether the warehouse door and delivery port are not tightly sealed, and timely deal with the problems of insulation and seal failure such as degumming and air leakage.The new cold storage material is made of rigid polyurethane or polystyrene foam insulation sandwich panel, which is made by high pressure foaming process and can be made into various lengths and specifications to meet the different requirements of the users.
Feasibility of the design scheme: the design of the quick-frozen warehouse can not be taken for granted. Many restrictive factors should be considered. In practice, a reasonable design scheme should be given according to local conditions. For example, the large-scale quick-frozen warehouse I built for my family should be refrigerated with ammonia in theory, because the refrigeration capacity of ammonia refrigeration is large, and I found that it is cheap to replicate cold through actual field investigation.system,Moreover, it can be replaced by ammonia compressor, but the exhaust temperature during use shall not exceed ℃, otherwise the oil viscosity will be reduced beyond the flash point and carbon will be formed, thus damaging parts and components.The combined cold storage door starts frequently or does not start for a long time, or does not stop for a long time,St. ClaudeHow much does it cost to install a cold storage, or stops before the storage temperature reaches.St. Claude,The service life of the cold storage depends on the quality of the refrigeration equipment, but it also has a great relationship with the proper daily management and maintenance after the installation of the cold storage. Many times, people often ignore the latter point. In daily life, as long as we maintain and maintain the cold storage regularly, we can greatly improve the service life of the cold storage and reduce the cost.The construction of small cold storage is widely used in life, such as food industry manufacturing industry, etc. since cold storage is so widely used, do you know cold storage? Especially the construction process and steps of cold storage. Understanding the construction process and steps of cold storage is helpful for all links of cold storage maintenance.The closed cell structure and surface material of polyurethane rigid foam with good moisture-proof, waterproof and corrosion resistance make it have better air resistance and water vapor resistance, and it can be made into inlaid connection structure during forming, which is easy to assemble. It does not need additional insulating layer to prevent moisture and saves a lot of trouble in laying insulating layer.