SoloraInstallation cost of fresh-keeping cold storageDesign advantages of

2023-03-08 03:12:32
632HP195506591energy184

Step of cold storage design: define the volume of the cold storage warehouse. The size of the cold storage should be based on the design of a large number of agricultural products to be stored for a long time. This volume is calculated based on the essential volume of stored goods accumulated in the cold storage, plus the row to row corridors, the indoor space between the pile and the wall, the ceiling and the gap of the packaging house. After the volume of the cold storage is determined, such as working intermediate, packaging and combing room, special tool warehouse, loading and unloading platform, etc.The exhaust temperature of the compressor equipment is often. When the season changes and the temperature difference changes greatly, pay attention to it. If the machine is abnormal, it needs to be checked in time.Solora,Conduit installation shall be beautiful and firm.Judge the operating sound of the compressor, and carefully listen to the operating sound of water pump cooling tower, compressor, fan and other equipment. In case of abnormal sound, timely warranty is required, so as to avoid greater damage to the compressor due to untimely warranty.Glasgow,The products stored in the medical cold storage project must be managed by color code, so as to avoid the problem of purchase errors. In the process of handling, it is also necessary to strictly follow the instructions.Moreover, polyurethane does not produce harmful gas at high temperature.The two sets of connectors between the cold storage shall be wedged tightly and the two sets of connectors shall be fixed at the upper, outer and lower sides of the cracks in the cold storage respectively. The lower connector shall be as close as possible, so as to facilitate the use of concrete to cover the connector in the future.


SoloraInstallation cost of fresh-keeping cold storageDesign advantages of



Now let's analyze the production and use requirements of the cold storage. There is no condensation in the cold storage. Condensation in the cold storage or in the insulation layer is harmful. During the drying process of the new wall or under winter conditions, it is impossible to condense in the wall due to the obstruction of the cold storage.The shelves in the warehouse shall have sufficient strength and rigidity.Proper protective measures shall be taken during transportation to prevent plate from being strangled and scratched.original,Anti odor floor drain shall be set on the pavement of refrigeration room and refrigeration unit room, and the height width ratio of floor drain water seal shall not be less than mm. The elevator shaft, electronic pit and other places convenient for drainage shall be provided with drainage and equipment to avoid backflow of water.There should be excellent drainage pipe standard around the warehouse, the soil temperature should be low, there should be interlayer under the cold storage, and maintain good natural ventilation. Maintaining dryness is very important for the cold storage. In addition, before the construction of the cold storage, the phase electricity of the relative volume shall be built according to the output power of the refrigeration unit. If the cold storage is water-cooled and radiating, the tap water pipeline shall be paved and the FRP cooling tower shall be built. - precautions for floor installation of cold storage: the floor shall be installed flat, the uneven part shall be leveled with materials, and the locking hook between the plates shall be locked to ensure that the warehouse surface is flat without hollow feeling. (note that if this drainage system is installed outdoors in the north, the drainage pipe shall be insulated).


SoloraInstallation cost of fresh-keeping cold storageDesign advantages of



The polyurethane insulation board shall be connected by plug-in notch connection, because it has higher strength when connecting in this way.Installation materials,SoloraQuick freezing and cold storage installation works,Initial stage of cold storage equipmentProtective fence shall be set around the door of the controlled atmosphere storage with eye-catching signs.Step of cold storage design: selection and laying of cold storage thermal insulation materials. The use of cold storage thermal insulation materials must be adjusted to the time, which not only has excellent fire resistance, but also has high cost performance. There are several types of cold storage insulation materials. One is the plate produced and processed into a fixed shape and specification, with fixed length, total width and thickness. The cold storage plate with relative specification and model can be selected according to the installation of the warehouse body. The high and medium temperature cold storage generally adopts cm thick cold storage plate cm or cm thick cold storage board is generally used for ultra-low temperature cold storage and freeze-cleaning cold storage; Another kind of cold storage can be sprayed with polyurethane spray paint and polyurethane foam, and the raw materials can be sprayed into the brick or concrete warehouse of the cold storage to be built immediately. After shaping, it is both waterproof and thermal insulation. Thermal insulation materials include polyurethane, polystyrene grease, etc. Polyurethane is non hygroscopic and has good fire resistance, but the cost is high; Polystyrene resin has strong water absorption capacity and weak fire resistance,It is equipped with temperature compensation to automatically adjust the water temperature. The water temperature of ultrasonic atomization is - degrees. If our humidifier is connected with the warehouse, there is no temperature compensation, even in the work, height and warehouse temperature of the cold storage on the basis of safety, science and rationality, from the perspective of energy saving and environmental protection. The lighting in the cold storage is concentrated in the working area.The quick freezing storehouse of vegetables and fruits is not suitable to use exhaust cooling,SoloraInstallation of small freezer, but use fan to supply air for refrigeration,SoloraCold storage by package, because the gas in the quick freezing storehouse needs to be circulated and dispersed regularly to avoid carbon oxide poisoning caused by high concentration of carbon oxide in local areas. Therefore, in the quick freezing warehouse, the refrigeration equipment needs to be used together with the air conditioning equipment. The selection of refrigeration equipment is different from that of low-temperature freezer and ordinary quick freezing warehouse.

404 Not Found

404 Not Found


nginx

Related articles

SoloraInstallation cost of fresh-keeping cold storageWhat's your opinion?

SoloraInstallation cost of fresh-keeping cold storageWhat's your opinion?

The construction of cold storage in site selection bears the circulation of low-temperature goods. T...

评论列表

466HP159575805
2023-03-08 10:42:19

So give praise! Just received the goods, very good, SoloraInstallation cost of fresh-keeping cold storage great value for money! ! Come in the future!

984HP143755493
2023-03-08 11:53:11

SoloraInstallation cost of fresh-keeping cold storage Very satisfied, good quality.

570HP155642700
2023-03-08 12:11:13

After looking for the SoloraInstallation cost of fresh-keeping cold storage from your family for a long time, I mustered up the courage and the quality of the inspection was very good.

256HP158312377
2023-03-08 11:22:39

The logistics is very fast, look forward to working together again

发表评论    

◎欢迎参与讨论,请在这里发表您的看法、交流您的观点。