NiorCost of small household elevatorsHow to treat the construction of ecological civilization

2024-03-02 01:58:25

Maintenance of elevator hall doors and car doors. Elevator malfunctions usually occur on the elevator hall and car doors, so attention should be paid to the maintenance of the hall and car doors. One is to refuel the fuel on the upper sill of the door and keep it in good condition, so that the elevator will not make unpleasant noises during operation and the opening of the door. Pay attention to the inspection of the safety contact plate or light curtain type contact plate switch wire of the elevator, as the frequency of opening and closing the door in the elevator is high, which can cause damage to the switch wire. This requires maintenance personnel to inspect it every time they work, and replace it in advance to avoid users having doubts about the quality of the elevator product due to door issues.The treatment of general civil engineering problems on escalator sites: the beam edge distance is too large: in this case, the length of the upper and lower platforms of the escalator can be increased to meet the actual dimensions of civil engineering. One platform can be extended on one side, or both platforms can be extended simultaneously. The total extension of the upper and lower platforms should generally not exceed mm. When lengthening the platform, attention should be paid to the length of the pit or the opening of the floor slab which should also be lengthened at the same time. After the escalator is extended, support needs to be added in the middle of the escalator truss. In addition, changing the angle of the escalator from degrees to degrees can also make the beam edge distance longer.Nior,Overloaded elevators do not operate: The load of elevators is limited, and if they are overweight, they will alarm and generally cannot be started. Most passengers can also voluntarily exit.Electrical components are roughly divided into screens, electrical switches for each safety circuit, etc. It is the brain of the elevator and the central nervous system of the elevator. The movement, operation, and door opening and closing of the elevator are all controlled by it so it must be treated as a top priority in daily maintenance work. Do not short circuit the elevator circuit inside the screen during work. When the elevator door system malfunctions, someone shorts the elevator door for convenience in order to find the fault. This is very dangerous, and there are many accidents when shorting the door. Why? If a person opens the hall door and extends their head inward, the elevator happens to run up or down to this point, and the hall door is shorted, the elevator cannot stop, so an accident is highly likely to occur. So in our daily maintenance work we must not short-circuit the safety circuit. If it is necessary to short-circuit, we must identify which safety component has a problem and which safety component needs to be shorted. Moreover, after maintenance or urgent repairs are completed, we must promptly remove the short-circuit wire. Professional household elevator manufacturer, with a large quantity and excellent quality at a reasonable price. It is fire-resistant, waterproof, high-temperature resistant, sturdy and durable,NiorMobile aluminum alloy lifting platform,NiorMobile reclaimer, safe and reliableZagreb,The front room of the fire elevator is equipped with indoor fire hydrants.Measurement of elevator shafts in new construction projects under different on-site conditions: When the building design is not yet completed, the operator only needs to provide the user with the standard elevator layout of the required elevator specifications, and the user entrusts the design department to design the elevator shaft. When the architectural design has been completed, and the site has not yet been constructed, is under construction, or has been completed, it must be determined based on the current construction or measured dimensions. If the original civil design of the shaft needs to be modified, the user should entrust the architectural design department to make the shaft design modification based on the layout provided by the elevator.The requirement for the shaft is that it should not be plastered which is beneficial for reducing noise, but there should be no protruding foreign objects.


NiorCost of small household elevatorsHow to treat the construction of ecological civilization



Please note that there should be a space of over mm left on both sides of the escalator, and when arranged in parallel, there is no restriction between the two escalators.When encountering abnormal elevator operation, you can call the repair hotline to consult with the maintenance personnel or inform the service center to handle it. Do not take unauthorized measures to avoid causing greater harm to the elevator or even causing casualties.The call button on each floor is no longer working, and the call is cut off.project,Please note that there should be a space of over mm left on both sides of the escalator, and when arranged in parallel, there is no restriction between the two escalators.The mechanical components of the elevator's traction machine require oil. There are two scales on the outer cover of the traction machine. Open the oil nozzle to check that the oil should be in the middle of the two scales. If the oil is lower than the lower scale, it means that the traction machine should be refueled. If not refueled, the elevator will not operate well for a long time, leading to the burning of the elevator traction machine and motor. After the elevator has been running for a long time, the oil should be replaced in a timely manner to keep the traction machine clean and in good condition.Multiple elevator shafts can be connected and an - # I-beam can be fixed at a certain height between each adjacent elevator shaft, with the same position as the ring beam. The pit must be equipped with an isolation net that is mm above the ground level.


NiorCost of small household elevatorsHow to treat the construction of ecological civilization



There is a dedicated fire telephone in the fire elevator car.Application process,The household must make two steel splints above the entrance. The position and size of the clamp plate are determined based on the selected door machine model.In daily life, it is necessary to determine whether the site has the conditions for adding support, as well as the range of support that can be added,NiorFully automatic hydraulic pressure for plate rolling machine, the height and load size of the equipment and support platform, and other parameters.Nior,If the elevator is in a downward direction, and automatically open the elevator door.The door closing button has no self maintenance function. During the designated maintenance period, the elevator components in operation are inspected, refueled, dust is removed, and safety devices are debugged. Including non-destructive testing and maintenance of elevator traction steel wire ropes.When the normal power supply is cut off, the lighting inside the non fire elevator has no power

404 Not Found

404 Not Found


nginx

Related articles

NiorCost of small household elevatorsHow to calculate the length of

NiorCost of small household elevatorsHow to calculate the length of

The door closing button has no self maintenance function. During the designated maintenance period,...

评论列表

275HP127226562
2024-03-02 10:43:51

The logistics of NiorCost of small household elevators is a bit slow. Overall it's good, I hope I have a chance to cooperate next time

914HP134131469
2024-03-02 10:16:59

The packaging NiorCost of small household elevators looks very good, the packaging is very careful, I believe the goods must be very good, thank you! Good value, huh, come again next time.

779HP136589660
2024-03-02 09:26:07

NiorCost of small household elevators Not bad, the price is worth it, just right.

984HP143755493
2024-03-02 09:37:51

I want to change a supplier and see you on the Internet, can I give a detailed explanation NiorCost of small household elevators

发表评论    

◎欢迎参与讨论,请在这里发表您的看法、交流您的观点。