AlvardenVertical barrier free elevator priceThe role of anticorrosive phosphating treatment

2024-02-28 00:00:21

Electrical components are roughly divided into screens, electrical switches for each safety circuit, etc. It is the brain of the elevator and the central nervous system of the elevator. The movement, operation, and door opening and closing of the elevator are all controlled by it, so it must be treated as a top priority in daily maintenance work. Do not short circuit the elevator circuit inside the screen during work. When the elevator door system malfunctions, someone shorts the elevator door for convenience in order to find the fault. This is very dangerous, and there are many accidents when shorting the door. Why? If a person opens the hall door and extends their head inward, the elevator happens to run up or down to this point, and the hall door is shorted,AlvardenSecond floor household elevator, the elevator cannot stop, so an accident is highly likely to occur. So in our daily maintenance work, we must identify which safety component has a problem and which safety component needs to be shorted. Moreover, after maintenance or urgent repairs are completed, we must promptly remove the short-circuit wire. Professional household elevator manufacturer, with a large quantity and excellent quality at a reasonable price. It is fire-resistant, waterproof high-temperature resistant, sturdy and durable, safe and reliableIn the event of a fire, when instructed by the fire center or the dedicated operation button of the first floor firefighter to enter the firefighting state, the elevator should immediately stop on the floor without opening the door, return to the first floor station, and automatically open the elevator door if it is in the upward direction.Alvarden,Passengers wearing long skirts and strapping sandals when riding on the escalator should try to stand slightly in the middle of the escalator to prevent shoes and clothing from being drawn into the escalator and causing danger, and to prevent skirts or pants from getting stuck.Multiple elevator shafts can be connected and an - # I-beam can be fixed at a certain height between each adjacent elevator shaft, with the same position as the ring beam. The pit must be equipped with an isolation net that is mm above the ground level.Beja,AlvardenFixed lifting rotating stage,There are dedicated operation buttons for firefighters at appropriate positions at the entrance of the first floor elevator. The operation buttons are generally protected by glass sheets and have a red&# quo; mark in place; Dedicated to fire protection; Words such as.To implement the arrangement of escalators and provide feedback, in order to determine the configuration of certain shared devices, the order of shipment, and the alignment of handrail turns during continuous arrangement.Tower style residential buildings above; Residential units and corridors with twelve or more floors; Other Class II public buildings with a building height exceeding meters; High rise buildings with elevators exceeding meters in height; The functional fire elevator has a front room. The area of the independent fire elevator front room is: the front room area of the residential building is greater than square meters; The front room area of public buildings and high-rise factory (warehouse) buildings is greater than square meters. When the front room of the fire elevator is shared with the smoke proof staircase, its area is: the area of the shared front room in residential buildings is greater than square meters, and the area of the shared front room in public buildings and high-rise factory (warehouse) buildings is greater than square meters.


AlvardenVertical barrier free elevator priceThe role of anticorrosive phosphating treatment



Attention: The elevator consists of two main parts: mechanical and electrical. If the elevator is not maintained on a daily basis, its safety cannot be guaranteed. If the elevator needs to be refueled without refueling, it will cause wear and tear on the mechanical components of the elevator greatly shortening its service life and preventing normal use of the elevator.When encountering abnormal elevator operation, you can call the repair hotline to consult with the maintenance personnel or inform the service center to handle it. Do not take unauthorized measures to avoid causing greater harm to the elevator or even causing casualties.The treatment of general civil engineering problems on escalator sites: the beam edge distance is too large: in this case, the length of the upper and lower platforms of the escalator can be increased to meet the actual dimensions of civil engineering. One platform can be extended on one side, or both platforms can be extended simultaneously. The total extension of the upper and lower platforms should generally not exceed mm. When lengthening the platform, attention should be paid to the length of the pit or the opening of the floor slab, which should also be lengthened at the same time. After the escalator is extended, the force on the upper and lower support points will also increase. If the edge distance of the beam increases too long, support needs to be added in the middle of the escalator truss. In addition, changing the angle of the escalator from degrees to degrees can also make the beam edge distance longer.quality index, immediately open the elevator door and enter the firefighter's dedicated state.Electrical safety. Faulty elevators have multiple safety devices, but there are also many places where problems can occur. Some people have been caught due to abnormal door opening and closing, taking the elevator is not about finding or acting in a movie. The real life is disturbed by the frequent elevator accidents, which make my heart feel uneasy


AlvardenVertical barrier free elevator priceThe role of anticorrosive phosphating treatment



The front room of the fire elevator is equipped with indoor fire hydrants.reform,The speed limiter tensioning device and the steel belt tensioning device should be equipped with a safety switch.As elevator people, let's talk about elevator and elevator safety knowledge: The elevators we currently use include box type passenger elevators escalators,AlvardenSemi-automatic reclaimer, and we don't use many of them. Now and dedicated cargo elevators. Dedicated cargo elevators are installed due to special needs, let's take a look at the safety knowledge of box type passenger elevators and escalators: When we take escalators, Be sure to follow the safety instructions when riding on the elevator. Do not crowd or play around, hold onto the elevator firmly, and avoid getting them caught up.Measure the length, width, and depth of the pit (if any), and observe whether there are grooves and embedded parts at the support beam.Alvarden,The mechanical components of the elevator's traction machine require oil. There are two scales on the outer cover of the traction machine. Open the oil nozzle to check that the oil should be in the middle of the two scales. If the oil is lower than the lower scale, it means that the traction machine should be refueled. If not refueled, the elevator will not operate well for a long time, leading to the burning of the elevator traction machine and motor. After the elevator has been running for a long time, the oil should be replaced in a timely manner to keep the traction machine clean and in good condition.Brick concrete structure elevator shaft: For unfinished brick structure shafts, users can be required to make a circle of beams at a certain height, arranged on three sides, and disconnected on one side of the elevator entrance. The distance between the center heights of the beams depends on the product model, and should not exceed mm. The beam height should be mm, and the thickness should be the same as the wall. The lower ring beam is -mm away from the bottom of the pit, and the higher ring beam is -mm away from the lower surface of the shaft roof. The completed framework with a solid brick structure shaft can be equipped with steel plywood at the position of the fixed guide rail support frame. The position and size of the plywood are provided by the elevator, and the user is responsible for providing materials and construction. If the shaft structure is made of hollow bricks without ring beams, steel beams can be considered to be added between the frames for rectification.Measurement of elevator shafts in new construction projects under different on-site conditions: When the building design is not yet completed, the operator only needs to provide the user with the standard elevator layout of the required elevator specifications, and the user entrusts the design department to design the elevator shaft. When the architectural design has been completed, and the site has not yet been constructed, is under construction, or has been completed, it must be determined based on the current construction or measured dimensions. If the original civil design of the shaft needs to be modified, the user should entrust the architectural design department to make the shaft design modification based on the layout provided by the elevator.


404 Not Found

404 Not Found


nginx

Related articles

AlvardenVertical barrier free elevator priceAssay method

AlvardenVertical barrier free elevator priceAssay method

The effective support width of the upper and lower support beams should be greater than the width of...

评论列表

275HP127226562
2024-02-28 08:05:51

AlvardenVertical barrier free elevator priceHow much is the best price, and I will give you a comment, can AlvardenVertical barrier free elevator price be cheaper?

695HP135175170
2024-02-28 07:33:42

The packaging AlvardenVertical barrier free elevator price looks very good, the packaging is very careful, I believe the goods must be very good, thank you! Good value, huh, come again next time.

535HP136858825
2024-02-28 08:27:37

AlvardenVertical barrier free elevator price Very good, I will order yours for the next batch.

发表评论    

◎欢迎参与讨论,请在这里发表您的看法、交流您的观点。