BanahachiLow temperature cold storage installation worksWeak stability and poor price
2023-03-13 01:40:37The foundation of cold storage is affected by low temperature, and the water in the soil is easy to be frozen. Due to the volume of frozen soil, it may even make the cold storage unusable. Therefore, in addition to the thermal insulation layer, the floor of low-temperature cold storage must be treated under the thermal insulation layer to prevent soil freezing. The bottom plate of the cold storage shall stack a large number of goods and pass through various loading, unloading and transportation machinery and equipment. Therefore, the structure of the cold storage plate shall be firm and have large bearing capacity. In low temperature environment, especially in the process of periodic freezing and thawing cycle, building structures are vulnerable to. Therefore, the structure of each part of the cold storage and the building materials of the cold storage should have sufficient frost resistance.Drainage measures shall be provided for the villa room and overhead layer of the road surface of the cold storage engineering building.Banahachi,For the selection and preparation of the ground location of the cold storage, the design of the cold storage shall consider the necessary auxiliary engineering buildings and equipment, such as working intermediates, packaging and combing room, special tool warehouse, loading and unloading platform, etc.Different food processing technical processes for the construction of cold storage are combined with local urban planning. The construction of cold storage is the design requirements and construction of cold storage, which not only avoids the cross pollution between foods, but also ensures its transportation facilities: within the construction scope, a reasonable overall layout,BanahachiInstallation cost of fresh-keeping cold storage, saves land and reduces costs.Al Mayadin, manufacturing industry, etc. since cold storage is so widely used, do you know cold storage? Especially the construction process and steps of cold storage. Understanding the construction process and steps of cold storage is helpful for all links of cold storage maintenance.Energy saving and power saving: the design cost of quick freezing warehouse mentioned above is very low, but it has a great impact on the cost of quick freezing warehouse and later use cost. The electricity bill is often an important expenditure item in the later stage. The design scheme of the show can greatly reduce the power consumption of the quick freezing warehouse. The selection of the back sunny side of the quick freezing warehouse, the selection of the thickness of the thermal insulation board should be appropriate, the tightness of the quick freezing warehouse door, and the temperature difference between the adjacent cold storage rooms should not be too large are all issues that we need to consider. There are also some tips, such as the use of air curtain machine on the quick freezing warehouse door. We remind users to use parallel units in quick freezing warehouse as far as possible and start them reasonably.Danfoss thermal valve is adopted for the thermal valve of the cold storage, with guaranteed quality; Due to the high temperature requirements of the cold storage and the high degree of automation and regulation of the temperature, the temperature system of the cold storage adopts microcomputer full-automatic, does not need special people to operate, it will automatically alarm, which is of great significance to the proper preservation of the cold storage.
The polyurethane insulation board shall be connected by plug-in notch connection, because it has higher strength when connecting in this way.If ammonia compressor is used, a special one shall be designated and the exhaust temperature shall be strictly controlled. When high pressure is applied, subsection shall be adopted to reduce the pressure differenceIndirect cooling is that the air in the warehouse is pumped into the air cooling device by the blower. The air is absorbed by the evaporation pipe circling in the cooling device, and then sent to the warehouse for cooling. The advantages of air cooling are rapid cooling, uniform temperature in the warehouse, and can bring harmful gases such as carbon oxide out of the warehouse during storage.Inspection requirements,In order to ensure the safety of construction and cold storage operation, the span between the top storage plate supports (lifting points) shall comply with the following provisions: the polystyrene top storage plate (mm thick) has a very large span of M, and the polyurethane top storage plate (mm thick) has a span of m.Moreover, polyurethane does not produce harmful gas at high temperature.With the development of the times, refrigeration devices are becoming more and more common. All aspects of life are inseparable from its use. Families will also be equipped with some simple refrigeration devices. For refrigeration devices such as cold storage, it is important to select materials with good thermal insulation. Cold storage is a better material selection, and manufacturers need to grasp its key points in the production process of cold storage.
We must often use insulation board in our life. It's just the structure of the refrigerator, but the refrigerator as a in the home, still has some use environment. In the market or marine transportation, the environment of cold storage insulation board is not so optimistic. Professional cold storage installation, cold storage installation, cold storage construction, fruit preservation cold storage, medical cold storage quality assurance. During the preferential activities, new and old customers are welcome to consult. The environmental differences inside and outside the cold storage insulation board are very large, because a large number of items need to be insulated, so the temperature in the cold storage is strict. In such cases, the cold storage insulation board will have relevant problems, Let's understand that the water vapor pressure outside the plate warehouse of the lower cold storage is higher than that inside the warehouse, and the penetration of the envelope is carried out from outside to inside all year round. R gas in polyurethane is replaced by air and water vapor to damp polyurethane. Over time, moisture becomes more and more serious, and even water vapor condensation occurs, resulting in low thermal conductivity and reduced thermal resistance. In order to avoid and delay polyurethane moisture and prolong the service life of the insulation layer, it is effective to seal the hot side of the insulation layer, that is, to form a vapor barrier layer.details,There are two kinds of refrigeration in the cold storage group: immediate refrigeration and simple refrigeration.Vacuum test: after the system pressure test is qualified, the system can be vacuum leak tested. The purpose is to improve the air tightness under vacuum conditions and prepare conditions for ammonia filling of the system.Floor insulation of small cold storage the structure of small cold storage is usually called surface that is, the top, wall and ground are made of color steel plate / stainless steel with appropriate thickness of polyurethane and other insulation materials because the loading and unloading of small cold storage is often handled manually rather than forklift. Of course, if the height of the warehouse is high and the forklift is required for warehousing, loading and unloading, the insulation board is not recommended for ground insulation but the ground needs to be insulated separately like the ground insulation sample of medium-sized cold storage.Banahachi,Improper adjustment or blockage of throttle valve,BanahachiInstall a cold storage installation, too large or too small refrigerant flow: improper adjustment or blockage of throttle valve will directly affect the refrigerant flow into evaporator. When the throttle valve is opened too large, the refrigerant flow is too large, the evaporation pressure and evaporation temperature also increase, and the decline rate of warehouse temperature will slow down; At the same time, when the throttle valve is opened too small or blocked, the refrigerant flow will also decrease, the refrigeration capacity of the system will also decrease, and the decline rate of warehouse temperature will also slow down.The butt joint between the top warehouse plate and the end of the top warehouse plate shall be treated to prevent air leakage and cold running. After all the top warehouse plates are installed, the butt joint shall be filled with foaming material, and the mm wide color steel plate shall be sealed at the butt joint with pull riveting.Core tip: in the cold storage project only with sufficient cold storage installation skills can we ensure that the cold storage is more energy-saving and power-saving after installation, convenient use and management and long service life.