RivasInstallation of drug cold storageWhat are the general steps
2024-01-20 02:56:16- Installation of the vertical plate of the cold storage: select the angle first according to the site conditions and locate it (i.e. lock the vertical plate and the floor) to extend to both sides at this angle. Only lock the vertical plate and the vertical plate, and locate it when it meets the vertical angle. Put the beautiful plate in a conspicuous place. When installing it on the side of the evaporator, make the drainage pipe in advance, and make U-bend and silica gel outside the storage.As a coolant, make it evaporate under low pressure and mechanical conditions to absorb the heat in the storage, so as to achieve the purpose of cooling.Rivas,However, due to high labor intensity and incomplete defrosting, it has limitations.The average service life of rigid polyurethane insulation structure with stable quality, long service life and high comprehensive cost performance can reach more than years under normal use and maintenance conditions. Under the normal service conditions during the service life of the structure, it will not be affected by drying, or electrochemical corrosion, as well as the growth of insects, fungi or algae or rodents.Kegayli,Emergency measures during the use of the medical cold storage project, it may also encounter power failure or power failure. In fact, most medical cold storage projects will be equipped with emergency equipment, so that the medical cold storage project can achieve the effect of normal power supply. Once the automatic temperature or humidity monitoring system is abnormal, the cold storage door should be closed in time So as not to expose more air conditioners, resulting in corresponding problems in the quality of stored products. The medical cold storage project also has a self rescue system in time. If the temperature of the cold storage exceeds the limit, the system cooling system will also be turned on. When the temperature returns to normal,RivasInstallation cost of cold storage, it will be automatically turned off.The temperature and humidity in the warehouse shall be kept uniform without movement; Try to finish the food in the warehouse at one time.The quick freezing storehouse of vegetables and fruits is not suitable to use exhaust cooling, but use fan to supply air for refrigeration, in the quick freezing warehouse, the refrigeration equipment needs to be used together with the air conditioning equipment. The selection of refrigeration equipment is different from that of low-temperature freezer and ordinary quick freezing warehouse.
The height of the warehouse, the horizontal and vertical of the warehouse shall be designed according to the refrigeration, refrigeration equipment, transportation and stacking conditions. The selection of insulation board is very important for Guangdong cold storage. At present, the vast majority of cold storage use polyurethane insulation board. What are the characteristics and advantages of polyurethane insulation board?Air tightness test: air tightness test of fresh storage system, also known as leak detection process, which can be divided into pressure, vacuum and ammonia filling leak detection stages.The foaming technology of polyurethane with strong stability makes it have superior bonding performance. The firm combination of polyurethane rigid foam and carrier layer is the basic premise to ensure the stability of external insulation layer. That is, under the unfavorable local temperature and humidity conditions, it can bear various internal and external combined loads such as wind force, self weight and normal collision, and the insulation layer still does not separate and fall off from the carrier layer and remains stable in the state.Development Curriculum,The overall construction achievements of the cold storage project have been put into use,RivasPrice and installation of cold storage, and the service life can reach years.Energy saving and power saving: the design cost of quick freezing warehouse mentioned above is very low but it has a great impact on the cost of quick freezing warehouse and later use cost. The electricity bill is often an important expenditure item in the later stage. The design scheme of the show can greatly reduce the power consumption of the quick freezing warehouse. The selection of the back sunny side of the quick freezing warehouse, the selection of the thickness of the thermal insulation board should be appropriate, the tightness of the quick freezing warehouse door, and the temperature difference between the adjacent cold storage rooms should not be too large are all issues that we need to consider. There are also some tips, such as the use of air curtain machine on the quick freezing warehouse door. We remind users to use parallel units in quick freezing warehouse as far as possible and start them reasonably.The overall construction achievements of the cold storage project have been put into use, and the service life can reach years.
Acid disinfectant can be used for mold removal and disinfection of quick-frozen warehouse.Where can I find it?The machine room of ammonia refrigeration system shall be equipped with exhaust assembly; The exhaust fan shall adopt anti motor. When the power supply is cut off due to unexpected refrigeration, it shall be able to ensure the reliable power supply of the exhaust fan. The overload protection of the exhaust fan should be applied to the signal alarm system without directly stopping the exhaust fan. The button box of the exhaust fan shall be concealed in the wall outside the ammonia compressor room. & amp; ldquo; Door to door & amp; amp; rdquo; & amp; amp; ldquo; Door to door & amp; amp; rdquo; Loading and unloading operation is the main operation mode to realize cargo circulation in logistics cold storage engineering.Cold storage plate features: good thermal insulation performance, light weight, high strength, corrosion resistance,RivasCold storage maintenance and installation, beautiful appearance.Rivas, we must combine the performance of the product and store it according to the temperature and humidity required by the product. The automatic temperature box also needs to be used outside the product cold storage. At the same time, the management personnel must be familiar with the operation steps of the medical cold storage project.In the low temperature environment, especially in the periodic freezing and thawing cycle, the building structure is also vulnerable to. Therefore, the building materials of the cold storage and the structure of each part of the cold storage should have sufficient frost resistance.Polyurethane refrigeration board uses light polyurethane as the internal material of refrigeration board. The advantage of polyurethane is very good heat insulation. The exterior of the cold storage is composed of SII, because the temperature difference inside and outside the board is large, and the temperature will disperse, which makes refrigeration more energy-saving and improves the working efficiency of refrigeration.