TodelgekoCost of small household elevatorsAnalysis of the reasons for popularity

2023-12-07 11:27:04

Machine room power supply: The power supply should be three-phase V, HZ, and the lighting power supply should be single-phase V, HZ. The incoming line should be connected to the vicinity of the machine room entrance and equipped with an incoming socket. Specializing in product and renewable resource business, including: home elevator manufacturersThe basic content of escalator shaft measurement is to measure the lifting height. The same as measuring the height of a straight ladder, strictly speaking, the lifting height of a ladder is the vertical distance between the finished ground at the upper and lower support beams. When using the suspension line method to measure, attention should be paid to whether there is a drop between the positioning point of the line drop and the decoration surface of the lower support beam of the ladder.Todelgeko,When passengers are riding on the escalator, they may lose their balance and fall due to leaning against the skirt board on the side of the escalator, which does not move, but their feet move with the steps. Especially when carrying a lot of packages while taking the elevator, it is more likely to fall on the escalator due to the inability to hold the handrail properly. So, when riding on the escalator, we must stand firmly and support it well, and do not lean against the skirt board on the side of the escalator.The requirement for the shaft is that it should not be plastered, which is beneficial for reducing noise, but there should be no protruding foreign objects.Yangiqurghon,The call button on each floor is no longer working, and the call is cut off.The door closing button has no self maintenance function. During the designated maintenance period, the elevator components in operation are inspected, refueled, dust is removed, and safety devices are debugged. Including non-destructive testing and maintenance of elevator traction steel wire ropes.In the event of a fire, when instructed by the fire center or the dedicated operation button of the first floor firefighter to enter the firefighting state, the elevator should immediately stop on the floor without opening the door, return to the first floor station, and automatically open the elevator door if it is in the upward direction.


TodelgekoCost of small household elevatorsAnalysis of the reasons for popularity



Tower style residential buildings above; Residential units and corridors with twelve or more floors; Other Class II public buildings with a building height exceeding meters; High rise buildings with elevators exceeding meters in height; The functional fire elevator has a front room. The area of the independent fire elevator front room is: the front room area of the residential building is greater than square meters; The front room area of public buildings and high-rise factory (warehouse) buildings is greater than square meters. When the front room of the fire elevator is shared with the smoke proof staircase, its area is: the area of the shared front room in residential buildings is greater than square meters, and the area of the shared front room in public buildings and high-rise factory (warehouse) buildings is greater than square meters.The elevator suddenly descends to the bottom floor and resumes normal operation: After the elevator is powered off and reconnected, the leveling reference position needs to be re determined.The mechanical components of the elevator's traction machine require oil. There are two scales on the outer cover of the traction machine. Open the oil nozzle to check that the oil should be in the middle of the two scales. If the oil is lower than the lower scale, it means that the traction machine should be refueled. If not refueled, the elevator will not operate well for a long time, leading to the burning of the elevator traction machine and motor. After the elevator has been running for a long time, the oil should be replaced in a timely manner to keep the traction machine clean and in good condition.Good qualityPlease note that there should be a space of over mm left on both sides of the escalator, there is no restriction between the two escalators.Brick concrete structure elevator shaft: For unfinished brick structure shafts and when arranged in parallel, users can be required to make a circle of beams at a certain height, arranged on three sides, and disconnected on one side of the elevator entrance. The distance between the center heights of the beams depends on the product model, and should not exceed mm. The beam height should be mm, and the thickness should be the same as the wall. The lower ring beam is -mm away from the bottom of the pit, and the higher ring beam is -mm away from the lower surface of the shaft roof. The completed framework with a solid brick structure shaft can be equipped with steel plywood at the position of the fixed guide rail support frame. The position and size of the plywood are provided by the elevator, and the user is responsible for providing materials and construction. If the shaft structure is made of hollow bricks without ring beams, steel beams can be considered to be added between the frames for rectification.The front room of the fire elevator is equipped with indoor fire hydrants.


TodelgekoCost of small household elevatorsAnalysis of the reasons for popularity



The treatment of general civil engineering problems on escalator sites: the beam edge distance is too large: in this case, the length of the upper and lower platforms of the escalator can be increased to meet the actual dimensions of civil engineering. One platform can be extended on one side, or both platforms can be extended simultaneously. The total extension of the upper and lower platforms should generally not exceed mm. When lengthening the platform, which should also be lengthened at the same time. After the escalator is extended, the force on the upper and lower support points will also increase. If the edge distance of the beam increases too long support needs to be added in the middle of the escalator truss. In addition,TodelgekoAluminum alloy mobile lifting platform, changing the angle of the escalator from degrees to degrees can also make the beam edge distance longer.Installation materials,If the elevator is in a downward direction,The speed limiter tensioning device and the steel belt tensioning device should be equipped with a safety switch.For escalators that require intermediate support and automatically open the elevator door.Aircraft weighing tens or hundreds of tons in the elevator hangar are vertically lifted onto the airport runwayMeasurement of elevator and escalator shafts (III)Todelgeko, it is necessary to determine whether the site has the conditions for adding support,TodelgekoStage boom elevator, as well as the range of support that can be added, the height and load size of the equipment and support platform, and other parameters.The shaft for updating the old elevator: The measurement of the shaft for the old elevator is the same as the shaft that has just been constructed. When the old elevator is not yet in use, try to obtain relevant data outside the shaft, such as the size of the machine room, floor height, and net size of the door opening. There are two situations when the old elevator is not yet in use: a. When the old elevator can start: in this case, the elevator technician must cooperate in measuring the shaft! And be sure to pay attention to safety! The elevator technician opens the hall door on the first floor and initiates maintenance operations to drive the car above the second floor. The measurement personnel open the floor door on the first floor to measure the pit data, such as whether the hall door is centered, whether there are brackets, whether there are special structures on the shaft wall, the spacing between ring beams, and the position of embedded parts. Then, the measuring personnel, with the cooperation of the technicians,TodelgekoVilla Home Seat Elevator, go up to the car roof and start the elevator at a maintenance speed. When the car roof is slightly lower than the sill of the second floor hall door, the measuring personnel observe and measure the full travel of the shaft from the top floor, mainly the height of the floor, while recording the measurement (safety must be paid attention to, and special attention should be paid to moving parts such as counterweights and wire ropes).


404 Not Found

404 Not Found


nginx

Related articles

TodelgekoCost of small household elevatorsIntroduction to inspection standards before leaving the factory

TodelgekoCost of small household elevatorsIntroduction to inspection standards before leaving the factory

Measurement of elevator shafts in new construction projects under different on-site conditions: When...

评论列表

78HP121928405
2023-12-07 11:41:34

TodelgekoCost of small household elevators Give me a discount next time, I wish you a lot of money

47HP158935852
2023-12-07 11:53:37

Finally got TodelgekoCost of small household elevators So happy that! The workmanship is great.

535HP136858825
2023-12-07 13:20:05

Old acquaintances, things are as good as always, genuine TodelgekoCost of small household elevators, outstanding cost performance

466HP159575805
2023-12-07 11:37:50

Dear, TodelgekoCost of small household elevators I received it, I love it very much, the workmanship is nothing to say, haha, the service attitude is also super good, a very caring seller, I will frequent it in the future.

409HP184720764
2023-12-07 12:06:12

It’s really a test and waiting. I finally waited for 3 days TodelgekoCost of small household elevators to arrive, the opening quality is very good

发表评论    

◎欢迎参与讨论,请在这里发表您的看法、交流您的观点。