XinjiAluminum alloy mast type lifting platformBring changes to the domestic market
2023-11-24 17:21:51If the elevator is in a downward direction, immediately close the door and return to the first floor station, and automatically open the elevator door.The mechanical components of the elevator's traction machine require oil. There are two scales on the outer cover of the traction machine. Open the oil nozzle to check that the oil should be in the middle of the two scales. If the oil is lower than the lower scale, it means that the traction machine should be refueled. If not refueled, the elevator will not operate well for a long time, leading to the burning of the elevator traction machine and motor. After the elevator has been running for a long time, the oil should be replaced in a timely manner to keep the traction machine clean and in good condition.Xinji,The elevator suddenly descends to the bottom floor and resumes normal operation: After the elevator is powered off and reconnected, the leveling reference position needs to be re determined.b. When the old elevator cannot start: due to the inability to enter the shaft, limited data can only be obtained from outside the shaft to determine whether it is non-standard (if there is a high platform in the machine room the plane size of the shaft can be measured in the machine room, but it is not accurate enough) for elevator quotation negotiation reference. In this case, the signing of the contract should state that the shaft rectification and costs are the responsibility of the user. For uncertain shaft structures and dimensions,Measure the beam edge distance between the upper and lower support beams. The measurement is to suspend the line from the upper support point to the ground for positioning, and then measure the horizontal distance from the positioning point to the edge of the lower support beam.Measure the length, width, and depth of the pit (if any), and observe whether there are grooves and embedded parts at the support beam.The basic content of escalator shaft measurement is to measure the lifting height. The same as measuring the height of a straight ladder, strictly speaking, the lifting height of a ladder is the vertical distance between the finished ground at the upper and lower support beams. When using the suspension line method to measure attention should be paid to whether there is a drop between the positioning point of the line drop and the decoration surface of the lower support beam of the ladder.
Measurement of elevator and escalator shafts (III)When passengers are riding on the escalator, they may lose their balance and fall due to leaning against the skirt board on the side of the escalator, which does not move,XinjiSightseeing elevator household use, but their feet move with the steps. Especially when carrying a lot of packages while taking the elevator, it is more likely to fall on the escalator due to the inability to hold the handrail properly. So, when riding on the escalator,XinjiHydraulic turnover machine, we must stand firmly and support it well, and do not lean against the skirt board on the side of the escalator.Multiple elevator shafts can be connected and an - # I-beam can be fixed at a certain height between each adjacent elevator shaft, with the same position as the ring beam. The pit must be equipped with an isolation net that is mm above the ground level.Installation conditions, limited data can only be obtained from outside the shaft to determine whether it is non-standard (if there is a high platform in the machine room, the plane size of the shaft can be measured in the machine room, but it is not accurate enough) for elevator quotation negotiation reference. In this case, the signing of the contract should state that the shaft rectification and costs are the responsibility of the user. For uncertain shaft structures and dimensions users should be reminded to provide them to the elevator after the old elevator or notify the elevator to take measurements before the new elevator is put into operation.There are dedicated operation buttons for firefighters at appropriate positions at the entrance of the first floor elevator. The operation buttons are generally protected by glass sheets and have a red quo; mark in place; Dedicated to fire protection; Words such as.To implement the arrangement of escalators and provide feedback, in order to determine the configuration of certain shared devices, the order of shipment, and the alignment of handrail turns during continuous arrangement.
Maintenance of elevator hall doors and car doors. Elevator malfunctions usually occur on the elevator hall and car doors, so attention should be paid to the maintenance of the hall and car doors. One is to refuel the fuel on the upper sill of the door and keep it in good condition, so that the elevator will not make unpleasant noises during operation and the opening of the door. Pay attention to the inspection of the safety contact plate or light curtain type contact plate switch wire of the elevator, as the frequency of opening and closing the door in the elevator is high, which can cause damage to the switch wire. This requires maintenance personnel to inspect it every time they work, and replace it in advance to avoid users having doubts about the quality of the elevator product due to door issues.Pursuit of excellence,For escalators that require intermediate support, it is necessary to determine whether the site has the conditions for adding support, as well as the range of support that can be added, the height and load size of the equipment and support platform,XinjiStage lifting platform, and other parameters.There are many similar situations in daily life, such as forcefully opening the door inside the car, causing the circuit to disconnect and forcing the elevator to stop, resulting in people being trapped. For example, if the elevator frequently enters and exits during decoration and falls into the crack of the door, and after several consecutive doors are opened and closed, the elevator will stop. Professional quality assurance for home elevator manufacturers. Discount activities are underway, and new and old customers are welcome to come for consultationThe call button on each floor is no longer working, and the call is cut off.Xinji, its area is: the area of the shared front room in residential buildings is greater than square meters, and the area of the shared front room in public buildings and high-rise factory (warehouse) buildings is greater than square meters.The call button on each floor is no longer working, and the call is cut off.